3.5.3 Light control
The light control consists of three different types of light: main light, slave light and inspection light. The primary
and slave light can be fitted with a light dimmer, and you can reduce the primary light for a period of time during
the day.
Dawn/dusk lighting can be simulated in one or two steps by selecting a light source with light-dimming. The light
dimmer can be installed with or without a relay.
Light dimmers with relays are used in houses where the light source used cannot be switched off by means of
the dimmer alone.
In addition, a light color control can be selected, which makes it possible to change the color of the light and
therefore simulate the changing colors of the sunlight.
Main light and slave light
Name
This is used to name a light source according to function, so that it can be recog-
nized in the menus and alarms.
Light sensor controlled
Selecting the light sensor control, so that the light sensor adjusts the lighting level
automatically.
Use boost
This is used for light fixtures that cannot be switched on unless they start at maxi-
mum power for a short period of time.
Light intensity unit
Setting if the light intensity should be adjusted in lux or as a percentage of maxi-
mum light intensity.
Reduce light
Only main light
Select if you should be able to reduce the main light for a period during the day
and naming according to the light source to be reduced.
Max. light intensity
Setting how wide a scale you should be able to adjust the light within. This en-
ables you to adapt the light control to the type of light source used in the house.
The scale can be set from 1-1000 lux and the factory setting is 100 lux.
Light dimmer boost time
Setting the duration of the boost when the light is turned on.
When light has been installed with a light dimmer, it can turn on using a so-called
boost. It means that it turns on with the maximum intensity and that it then adjusts
according to the setting.
Inspection light
Inspection light
Setting for how long the inspection light should be switched on.
Select the light sources for inspection light.
When a light source has been installed with a light dimmer, a required light inten-
sity for the inspection light can also be set.
Light sensor
Light sensors
Setup of which light source the individual sensor is to be connected to. The con-
troller regulates according to an average value if several light sensors are set up
for the same light source.
When installing light you must decide how the function is to re-
act in an emergency situation.
Yes:
In case of control failure, the light is on.
No:
In case of control failure, the light is off.