background image

6

Operation

User Manual

SERENE HB80/110

2

  Operation

Cabinet Operation

If the cooler has been disconnected from the power supply for any reason, 
allow about 10 minutes before switching it back on. This allows the 
refrigeration system pressure to equalise before the system is restarted.
Before operating the cooler, ensure:

The cooler is positioned on a level surface.

The maximum operating temperature is no greater than 32°C.

There is adequate ventilation around the refrigeration system.

There is a gap of at least 50mm around the cabinet.

The plastic drain pin (included in the bag with the user manual) is placed 
into the drain hole at the bottom of the cabinet (see image below). This 
prevents objects from covering the drain hole.

The cabinet stabiliser foot is screwed firmly down to floor level (see 
image below). 

The cooler is allowed to stand for at least 30 minutes before connecting 
to the power supply.

While the cooler is operating it is normal to hear gurgling sounds caused by 
the flow of refrigerant when each cooling cycle ends. 

Refrigeration

System

The evaporator fan (located inside the cabinet) should operate continuously 
from the time the cabinet is plugged in.  This may be verified by checking for 
air movement inside the cabinet. The thermostat will click when the 
refrigeration system cycles on and off.

Cabinet Light

The cabinet interior light is controlled by the light switch next to the 
thermostat knob inside the cabinet (see Figure 4 on page 9). The fluorescent 
light will require a period of time to stabilise following initial start up. See 
page 10 for instructions on replacing the fluorescent lamp.

Loading

The cooler should be left running for 30 minutes to allow the cabinet to cool 
down before loading with product. When loading the cabinet shelves with 
product:

Allow air space around all the product for even cooling and efficient 
operation of the cooler.

Do not exceed a maximum of 30 kg per shelf.

Do not allow products to overhang the front or rear of the shelves, as 
this will affect air flow.

Do not obstruct air flow from the evaporator fan (inside the cabinet).

Do not block the drain hole inside the cabinet.

Stabiliser foot

Drain plug

Содержание serene HB110

Страница 1: ...User Manual MAN6819 Rev 5 3 Jan 2017 HB80 110 SERENE Glass Door Cooler from SKOPE ...

Страница 2: ...800 947 5673 New Zealand SKOPE 1 year Extended Warranty Extend your Warranty Protection by 1 year during registration Please check you have not already organised an extended warranty through your dealer at time of purchase For pricing information on an extended warranty visit www skope com warrantyprotection Service Support We know you will get years of satisfaction from your new SKOPE product whe...

Страница 3: ...st 4 Unpacking 5 Shelves 5 Positioning 5 Power Supply 5 Ventilation 5 Location 5 Levelling 5 2 Operation Cabinet Operation 6 Refrigeration System 6 Cabinet Light 6 Loading 6 Temperature Adjustment 7 3 Maintenance Cleaning 8 Cabinet 8 Condenser Coil 8 Interior Light 9 ...

Страница 4: ... is essential to economical high performance Be careful not to touch moving parts and hot surfaces For your own safety and that of others ensure that all electrical work is done by authorised personnel If the power supply flexible cord becomes damaged it must be replaced by an authorised service agent or similarly qualified person in order to avoid a hazard This appliance is not designed to be sta...

Страница 5: ...easily accessed once the cabinet is positioned so the cabinet can be disconnected from the power supply for cleaning and maintenance Ventilation Ensure adequate ventilation is provided around the cooler The cooler should not be recessed or enclosed in a cabinet It is designed for free standing installation only The recommended clearance on both sides and at the back of the cabinet is 50mm The maxi...

Страница 6: ...by the flow of refrigerant when each cooling cycle ends Refrigeration System The evaporator fan located inside the cabinet should operate continuously from the time the cabinet is plugged in This may be verified by checking for air movement inside the cabinet The thermostat will click when the refrigeration system cycles on and off Cabinet Light The cabinet interior light is controlled by the ligh...

Страница 7: ...not require adjustment The thermostat knob is graduated from 0 through to 6 with 1 being the warmest and 6 being the coldest The normal temperature controller setting is between 2 and 3 If further adjustment is required To make colder turn the thermostat knob clockwise To make warmer turn the thermostat knob anti clockwise Turning the knob to 0 will switch the cooling system off fan and lights sta...

Страница 8: ...ter Disconnect the cabinet from the power supply before cleaning When necessary wipe both the interior and exterior of the cabinet with a damp cloth Do NOT flush the cabinet with water Clean the door gasket once every three months Periodically check the condensation drain hole inside the cabinet to ensure proper drainage of any condensation Condenser Coil The condenser coil is located at the back ...

Страница 9: ... the interior light tube 1 Disconnect the cabinet from the mains power supply 2 Remove the light cover by carefully bending out the side clips 3 Pull the fluorescent lamp out of the lamp holder 4 Replace with a maximum 5 Watt fluorescent lamp 5 Carefully align the side clips on the light cover and fit back into place 6 Reconnect the cabinet to the mains power supply ...

Страница 10: ...ark to the product after their state condition get up or packaging has been altered in any manner Alters removes including part removal or obliterates including part obliteration the trade mark on the product Applies any other trade mark to the product Adds to the product any written material that is likely to damage the reputation of the trade mark Notice of the above contractual obligations pass...

Отзывы: