TCE1000N
Replacement Procedures
Service Manual
Cleaning
Cabinet
Wipe the inside and outside of the cabinet with a damp cloth, taking care to
keep moisture away from electrical parts. As with any maintenance, ensure
the chiller is unplugged from the power supply before cleaning.
Condenser
Coil
To ensure trouble-free performance, the condenser coil must be kept clean.
We strongly urge monthly cleaning with a soft brush to remove dust and fluff.
A more thorough cleaning is required by qualified service personnel every
six months. The condenser coil
must
be kept clean for efficient and reliable
operation.
To clean the condenser coil and optional condenser filter
WARNING
Unplug the chiller from the power supply before cleaning the
condenser coil.
1. Unplug the chiller from the power supply.
2. Use steps or a platform to
access the back of the
sign, and unscrew the two
wire cover screws (located
above the back of the
electronic controller
housing).
Note:
Image
shows back of sign with
cabinet side removed.
3. Swing the sign out from
the cabinet and unplug the
3× plugs. Lift the sign off
and place aside.
4. Brush the condenser coil
with a soft brush to
remove any dust and fluff.
Wire cover
screws
Illuminat
ed Sign
Interior Light
Front panel
Condenser coil