InMan DL1-Multi Single Axis Doppler Speed Log System
InMan DL1-Multi Single Axis Doppler Speed Log System
Electronics AS
Electronics AS
Color Code
Signal
Screen
Color Code
Pair
Screen
White
+18-36 V DC
Individually
screened pair
Brown / White (blue)
Pair
Common screen
Black
0 V
Blue (brown) / Blue (white)
Pair
Yellow
TX+
Individually
screened pair
White (green)
Pair
Black
TX-
Green (white)
White
RX+
Individually
screened pair
White (orange)
Pair
Orange
RX-
Orange (white)
Yellow
Aux+
Individually
screened pair
N/A
Pair
Orange
Aux-
N/A
To be grounded
together and
passed into the
outer screen of the
Cat5e cable
The
JuncTion
BoX
JB12,
anD
caBLe
eXTensions
Sensor cable
Extension cable
Colour Description (seen
from JB70XX)
Screen
Colour (for CAT6)
White
+18 - 36 V DC
Individually screened pair
Common screen
Brown
Pair
Black
0 V
White(Brown)
Orange RX+
Individually screened pair
Orange
Pair
White
RX-
White(Orange)
Black
TX+
Individually screened pair
Green
Pair
Yellow
TX-
White(Green)
Orange AUX+
Individually screened pair
N/A
Pair
Yellow
AUX-
N/A
All individual screens to be grounded together and
passed into the outer screen of the CAT5e cable
Outer shield
Connect the sensor cable
to the Extension cable as
shown. All grounds are
collected together and
connected to the outer
ground of the Extension
cable. The grounds should
not
be connected to a local
ground. If there is no room
for the JB12 housing, the
cables can be carefully
spliced together. Both cables
can be cut.
C
able
diagram
Cd402XX-SC
Signals
Pin number on
plugable WAGO
back connector
+24 V
1
0 V
2
NMEA IN A
3
NMEA IN B
4
DIM UP A
5
DIM UP B
6
DIM DWN A
7
DIM DWN B
8
NMEA2 IN A *
9
NMEA2 IN B *
10
NMEA1 OUT A
11
NMEA1 OUT B
12
Note: NMEA in/out is not in use on
LAN set up.
Wago
connector
LAN
connector
cD402 c
onTroL
uniT
To
e
LecTronic
uniT
The CD402XX-SC is powered by local 24VDC on pin 1 and 2 on Wago connector.
Connection to Electronic with LAN connector directly or via LAN switch.
Alternativ 2
Connect CD402 Control unit to JB70D1 via LAN switch
Alternative 1
Connect CD402 Control unit to JB70D1 directly.