InMan DL1-Multi Single Axis Doppler Speed Log System
InMan DL1-Multi Single Axis Doppler Speed Log System
Electronics AS
Electronics AS
Connect the units together and use SKIPPER
service software to find the relevant settings,
alternatively address indivdual units using
their IP addresses from a web browser
If no switch is available, connect directly to each
unit and use its web page to setup. Multirepeaters
can be set up directly from the screen.
CHAPTER 3: SETUP LAN COMMUNICATION
Both the Control unit and the Electronic unit have unique IP addresses, and system identification
numbers. These are adjustable via the web page, but the default values are shown on the serail
number labels. If changed it is recomended to make a label with the new address.
Startup requires the following steps:
s
eTup
using
skipper
service
sw
For setup of IP adresses, Id and port please use
SKIPPER service software.
Available as download from:
Start “Com Setup”
Note! If no DHCP server on network then change
your PC TCP IP settings to “fixed IP”.
Press “Find multi systems”
The software will search for SKIPPER products and present a list with settings. A table wth all the detected
system will be generated. and from this table it is possible to configure the units. Each Electronic unit
JB70D1-SA must be paired with a control unit (CD402CU-SC) This is done by adding the identification of
the JB70D1 unit to the Control units pair field.
If more than one control unit is to be used on a single Electronic unit then the field Pair field on the
electronic unit (JB70D1) can be left blank. Otherwise enter the ID for the paired control unit.
Note. All units that are to detect eachother must be in the same Group. this is by default NAVD.
System ID: The unique (SFI) ID of this unit
Unit serial number (fixed)
IP address for web page
Group the system belongs to
System ID of the unit that this system is to be
uniquely connected to (CD402CU must have.)
Name for the unit (max 20 characters)
CD401CU shows error
if it does not detect the
JB70D1-XX unit
Lan
seTup
Turn on the electronic unit and contol unit (if attached). The electronic unit will attempt to self-
connect, and go to the system setup screen. If the control unit is not available or does not work,
(possibly IP clash) it will show a single ‘ERROR’ on screen, in this case connect a LAN cable to a
RJ45 connector.
Go to web page (default IP address
172.16.1.104 for JB70D1 or 172.16.1.103 for CD402CU,or
to
the labelled IP address. From here you have access to the system setup page. If you can not make
contact by the above methods, use the SKIPPER service application (available from the web site,
select the correct interface unit, and follow the instructions.
In accordance with the IEC61162-450 LAN interface standard, the System Unique identifier (default
VD01XX where XX is the serial number) and Group (default NAVD) can be adjusted. The LAN
works at 100BaseT speeds. A typical payload will be 2-7 kB/s
UdPbC0\s:VD0103,n:23*2A\$VDVBW,10.1,,A,,,V,,V,,C*58<CR><LF>