The user can run an internal system test, run individual hardware tests and report as pass or fail.

The tests are designed to check the functionality of the input and output. Some require a loop from 

an input to an output.

Test 0: Check LEDs on CD401CU-XX control unit.

Test 1: Check internal memory.

Test 2: Check two way communication to the sensor.

Test 3: Send out a full length NMEA message on NMEA outputs.

Test 4  Send out a full length NMEA message on sensor outputs.

Test 5: Used only for manufacture test

Test 6: Used only for manufacture test

Test 7: Used only for manufacture test

Test 8: Used only for manufacture test

Test 9: Used only for manufacture test.

Test 10: Show Raw data from the sensor, and Quality factor 

 

Quality factor is a value from 0 to 8 showing how strong the signal is relative to the noise. If the 

installation is poor, the noise may rise reducing this number, also if the return signal is weak, this value 

will also be low. Each unit is 3dB signal to noise ratio. The system is suspect with values below 3.  .

 

 

r

unning

 

in

 

DeMo

 

MoDe

Once all parts are installed, the system can be made to run simulations of real situations. These are 

found in the demo setup.  

The system has 4 demos:

Demo 1:

 Slowly ramps a speed up and down. This allows the user to monitor 

 

    speed outputs, to set and trigger alarm (which can then be reset).

Demo 2:

 Fixes a speed on screen. This can be preset in the web page.

Demo 3:

 Transmits a fixed speed of longitudinal 5 kn and transversal 1 kn.

Demo 4:

 Simulates a speed on the sensor by pinging at the equivalent Doppler 

 

    frequency - select the desired speed and press “SET”. 

All these demo/simulations will cause an ‘S’ to flash in the corner of the

CD401CU-XX control unit.

Содержание DL1-Multi

Страница 1: ...no 0612 Oslo Norway Co reg no NO 965378847 MVA www skipper no Document no DM M004 SA Revision 1425A For software ver 1 61 Date 2021 12 10 BRIDGE FORE PEAK 115 230VAC 24VDC CD402CU Operator Unit for D...

Страница 2: ...s Weitergabe sowie vervielf ltigung dieser unterlage verwertung und mitteilung ihres Inhaltes nicht gestattet soweit nicht ausdr cklich zugestanden Zuwiderhandlungen verpflichten zu schadenersatz Tout...

Страница 3: ...24 LAN setup 25 CHAPTER 4 WEB SETUP OF SPEEDLOG 26 CD402CU communication with JB70DL 26 JB70DL communication with CD402CU 27 JB70D1 NMEA setup 28 JB70D1 AUX setup 29 CD402 Control Unit Self Test 30 R...

Страница 4: ...act single euro cabinet This units electronics enable the user to interface to both modern and older navigation systems with all the expected connectivity The unit has a built in web server allowing t...

Страница 5: ...SA Dimmer NMEA pulses IR30DIM SA Dimmer pulses I O DL1 CD402CU Operator Unit for DL1 JB70DL1 SA Electronic Unit LAN cable CAT6 Max 100m JB12 Junction box DL1SG SA DL1 sensor w 40m cable in Sea valve...

Страница 6: ...lister should be constructed It is recomended to allow a flat area of at least 30 cm in front and behind of the sensor and form the bed as a tear drop A Bubbles Sensor installation A Bubbles Side view...

Страница 7: ...ws M8 with lock washer Torque 40Nm 3 Screw the 2 Nuts M16 sligtly up to the Clamp Unit 4 Tighten the 2 Nuts M16 with lock washer on 1 2 3 4 Mounting order Nut M50 and Clamp Unit the opposite side Torq...

Страница 8: ...ng DIN rail EN 50022 min 260 mm A 7 6 DETAIL A SCALE 2 1 IP22 approved mounting 1 2 3 4 3 2 1 5 C D 4 6 7 8 A B Electronics AS E ISO2768m 1 2 Gen tolerance Eur projection XXX Material 2013 04 29 Check...

Страница 9: ...ensor to Electronic unit The sensor is provided with a 40 m cable This can be cut or extended see wiring diagram for cable spec The individual internal wires can be spliced or connected using a JB12 j...

Страница 10: ...k TX Individually screened pair Green Pair Yellow TX White Green Orange AUX Individually screened pair N A Pair Yellow AUX N A All individual screens to be grounded together and passed into the outer...

Страница 11: ...put to the NMEA input of JB70D1 Electronic unit The IR31taking up to 2 NMEA lines and multiplexing onto it a DDC or Proprietry message each time a button is pushed Auto mode with internal or external...

Страница 12: ...te Orange Yellow Black DL1S PULSE LEVEL OUTPUT BROWN ORANGE GREEN NMEA 2 OUT _ NMEA 1 OUT _ 01 R1 R2 NMEA IN 24V SENSOR OV SENSOR SENSOR IN _ SENSOR OUT AUX SENSOR OUT AUX 1 OUT AUX 2 OUT AUX 1 IN NCN...

Страница 13: ...ntrol unit CD402CU SC This is done by adding the identification of the JB70D1 unit to the Control units pair field If more than one control unit is to be used on a single Electronic unit then the fiel...

Страница 14: ...0DL Setup can be performed from web browser preferably chrome or mozilla available by connecting a PC to the LAN port using a tLAN cable WEB browser for CD402 is just for setup of communication to the...

Страница 15: ...itudinal speed in knots y y is transversal in 2 axis systems speed in knots VLW Distance Travelled through the Water VDVLW x x N y N N N hh C R LF x x is Daily Trip y y is total trip in NM MTW Tempera...

Страница 16: ...only for manufacture test Test 10 Show Raw data from the sensor and Quality factor Quality factor is a value from 0 to 8 showing how strong the signal is relative to the noise If the installation is...

Страница 17: ...al For Calibration on web page Open web browser with I P adress to JB70D1 Electronic unit Goto Calibration and start Auto Calibration Set distance of first leg The leg should take at least 5 minutes t...

Страница 18: ...ect the item to be tested upgraded and follow the instructions New software updates can be downloaded from the website or via this software Live view of sensor RAW data The system has 3 main ele 1 Und...

Страница 19: ...k port and IP set up Chapter 3 Setup LAN Communication on page 24 ERROR COM CD402CU detects the JB70D1 XX unit but JB70D1 is sending message that it does not receive any message from CD402CU STW ERROR...

Страница 20: ...l the receiver part of the standard however by connecting the common signal ground to pin 10 marked Common the transmitting part of the standard is fullfilled IEC61162 450 ethernet communication The s...

Страница 21: ...ough Water STW data to control units and other inte grated navigation systems To be used with CD402CU XX DL1SX XX Control unit compact with LAN Log sensor for SB DB 60 SA Doppler 40 m The junction box...

Страница 22: ...Page 42 of 48 Date 2021 12 10 Date 20121 10 10 Page 43 of 48 InMan DL1 Multi Single Axis Doppler Speed Log System InMan DL1 Multi Single Axis Doppler Speed Log System Electronics AS Electronics AS...

Страница 23: ...and a switch is not available it is possible to connect the CD402CU via NMEA communications In this case the connector on the rear of the CD401 NMEA out should be connected to NMEA IN in the JB70D1 XX...

Страница 24: ...channel Goto setup by pressing Menu and Set at the same time Press down to highlight Filtr Press Set Set Filtr to ON by pressing UP button Exit by pressing Menu and hold for 1 second Indication of on...

Страница 25: ...SKIPPER Electronics AS Telephone 47 23 30 22 70 Enebakkveien 150 Telefax 47 23 30 22 71 P O Box 151 Manglerud E mail support skipper no 0612 Oslo Norway Co reg no NO 965378847 MVA www skipper no...

Отзывы: