background image

 

 

REV. 2 

/08.11.2011 

CE/ab 
70016GB 
 
 
 
 
 
 
 
 
 
 

INSTRUCTION MANUAL 

 

SKIOLD UNI-MIX 1000 GM

 

 

TYPE NO. 590061 

 
 
 

SKIOLD A/S 
Kjeldgaardsvej 3 
DK-9300 Sæby 
Denmark 
Tel.: +45 99 89 88 87 
Fax: +45 99 89 88 77 
[email protected] 
www.skiold.com 

Содержание UNI-MIX 1000 GM: 590061

Страница 1: ...2 08 11 2011 CE ab 70016GB INSTRUCTION MANUAL SKIOLD UNI MIX 1000 GM TYPE NO 590061 SKIOLD A S Kjeldgaardsvej 3 DK 9300 S by Denmark Tel 45 99 89 88 87 Fax 45 99 89 88 77 skiold skiold com www skiold...

Страница 2: ...DISMOUNTING THE MIXER 17 11 0 TECHNICAL SPECIFICATIONS 18 12 0 EX ZONE SPECIFICATION 19 13 0 ACCESSORIES 20 14 0 SPARE PARTS LIST 21 15 0 CE ATEX DECLARATION OF CONFORMITY 22 2 0 FIGURES Fig 1 Mixing...

Страница 3: ...N 50014 DS EN 50281 1 1 and DS EN 50281 1 2 In order to observe the unified standards regarding dust explosions DS EN 1127 1 and DS EN 13463 1 the mixer must be equipped with cover and inspection and...

Страница 4: ...components to be mixed can be added through the mixer top or lower filling door Material addition from a hammer mill is normally done through the mixer cover via a cyclone Concentrates are added by me...

Страница 5: ...ssembled with the auger The unit is transported to the required place on the attached wheels 5 3 Mounting of Motor and Gear Motor and gear are supplied separately and the motor is only mounted on the...

Страница 6: ...6 Fig 3 Mounting flange for motor The motor is fastened with the enclosed 4 pcs M12x30 bolts with belonging discs Fig 4 Mounting of motor on gear...

Страница 7: ...mixer auger Mount the gear figure 6 pos 2 on the shaft of the mixer auger and secure it with disc and bolt Connect the gear to the instantaneous bracket pos 5 with rubber bushings pos 4 and distance...

Страница 8: ...10x16 screws and belonging nuts and discs Bolt cover for hopper pos 9 onto the lower front plate pos 14 with M6x16 flange screws and belonging flange nuts Safety grate beneath the cover should be moun...

Страница 9: ...11 10 27 7 9 25 24 14 22 15 6 5 30 31 5 5 Mounting of Emptying Auger Fig 8 Mounting of emptying auger Pos 1 Auger trough Pos 2 Q20 clamp Pos 3 102 mm single or double auger outlet Single emptying aug...

Страница 10: ...op excess pressure valve 1 bar Pos 4 Inlet pipe adjustable in the height It is recommended to add the liquids approx over the mixer outlet as there is always material here irrespective of the size of...

Страница 11: ...Mounting of Ventilator Fig 10 Mounting of ventilator Place filter and ventilator cornerwise in two separate corners of the cover as shown in figure 10 It is of no importance which side of the mixer is...

Страница 12: ...ed faulty load may occur causing faulty weighing Mount a swivel pin with conical nut on each load cell Place the steering hole of the mixer foot over the conical nut as shown in figure 11 Fig 11 Mount...

Страница 13: ...onnections to weighing system Pos 1 Suspension iron Pos 2 Cyclone auger Pos 3 Flexible connection Pos 4 Mixer Augers cyclone etc may not rest on the mixer Also use flexible connection to emptying auge...

Страница 14: ...grain sufficiently dry for storage or from moisture proof silo with max humidity of 25 Mixing with addition of up to max 6 fat oil or molasses added continuously during operation of the mixer Limitati...

Страница 15: ...inlet is not blocked The mixer must be started now and then during the intake or alternatively started for a while between addition of each component minimum 1 minute Liquids must always be added as l...

Страница 16: ...The plug must be unscrewed for check of the oil level Fig 14 Oil level of the gear Lubrication interval Oil change every 20 000 operation hours Oil type Mineral oil ISO VG 220 or similar type Quantity...

Страница 17: ...ault cause and repair The mixer does not start Mechanical fault Check motor gear and auger connection Foreign bodies in the mixer Check the mixer The motor does not start Thermal contact released beca...

Страница 18: ...x 40 CCM max 600 kg CCM max 50 humidity Addition of fat oil and molasses max 6 Mixing time 10 15 minutes Emptying time 5 10 minutes Inclination 27o Motor 1400 rpm 4 kW Transmission Gear i 34 91 Weight...

Страница 19: ...er is zone 21 In order to observe above zones the mixer must be equipped with cover and the inspection and filling doors must be closed while the mixer is in operation or the mixer is filled by the me...

Страница 20: ...9 Ventilator with filter 590024 Emptying auger 102 single 1 1 kW 280 rpm 590093 Emptying auger 102 single 1 1 kW 560 rpm 590094 Emptying auger 102 double 1 1 kW 280 rpm 590095 Emptying auger 102 doubl...

Страница 21: ...1 14 0 SPARE PARTS LIST Pos Code No Description Wearing part 20 591026 Mixer auger x 44 6407077 Bearing 2 19 6801007 Gear I 34 91 1 2320093 Motor 4 kW 1400 rpm B5 IEC112 Fig 17 Spare parts 1 19 44 20...

Страница 22: ...1000 GM with motor 590061 was constructed and manufactured in conformity with the following directives Directive Standard CE ATEX directives 2006 42 EC and DS EN ISO 12100 1 1994 09 EC with revisions...