SKIMO B PLUS 1KW 24V – AIR CONDITIONING UNIT
CODE PRODUIT : 320B21
INSTALLATION, USER AND MAINTENANCE MANUAL
Page 4/21
The Skimo A/C unit contains moving parts that represent a danger. Do not disable the security features. Switch the
Skimo unit and the machine or vehicle off before opening the unit or taking the cabin panel off.
The A/C refrigerant circuit is under pressure. Do not open the A/C refrigerant circuit. This would create a loss of
refrigerant gas that is colourless and odourless. It could create serous burns. The personal performing the repair or
maintenance of the A/C refrigerant circuit must be qualified to manipulate such systems and must use appropriate tools,
equipment and protection equipment. Wear protection goggles and gloves when you maintain the Skimo unit. Rejecting
refrigerant gas in the atmosphere is strictly forbidden.
The Skimo A/C unit must be maintained and cleaned up regularly from dust, vegetal or other wastes or
combustibles to avoid risks of fire.
Use only original spare parts.
3. TECHNICAL CHARACTERISTICS OF THE SKIMO A/C UNIT
The technical specifications or characteristics of the Skimo A/C unit, as they are described in this manual, are subject to
change without notice.
SKIMO is a self contained air conditioning with: air conditioning components (condenser, evaporator, drying filter,
compressor …), electrical components (electrical motor, fan, blower, harness, fuses), and a ceiling panel with controls
and air outlets.
The Skimo A/C unit is pre-charged with R134a refrigerant gas.
•
External dimensions (+ or - 2cm): length 72 cm, width 48 cm, height 25 cm
•
Cabin ceiling panel dimensions (+ or - 2cm): length 29 cm width 39 cm thickness 6 cm
•
Weight: 35 kg (+ or – 3 kg)
•
Evaporator cooling capacity: 3500 W with +31°C air intake and 50% air humidity.
•
Maximal consumption: 960W (that is 80 Amps electrical current for a 24V to 55°C outside temperature)
•
Refrigerant HFC R134a quantity (+ or - 10g): 700g
•
Oil: PAG 150 46 (SNDC Ref 430A08)
With its CE label, Skimo meets the main health and safety requirements of the 2006/42/CE directive. See CE statement in
appendix.
The Skimo A/C unit can be mounted on ant vibration studs. In this case, there must be a sufficient number ant
vibration studs, they must be distributed evenly to offer proper and even support to the unit. All the instructions
contained in this manual must be followed, including the instructions about cantilevered positioning. The water tightness
between the roof and the unit must be kept.