15.a To plug the service centre hoses (to check pressures, recover the gas, charge the A/C system…):
1. Remove the 6 fastening screws of
the unit cover, lift the cover and
unplug the ventilator connector.
2. Remove the maintenance access
plug circled in blue.
3. Unscrew the A/C service centre
hoses couplers, pull the hoses through
the maintenance access hole, and
screw the couplers back on. Connect
the couplers on the pressure ports.
4. Plug the ventilator connector back
on and put the cover back into place.
The unit can be turned on to check the
pressures.
5. Once the pressure check completed,
remove the service centre hoses, put
the maintenance access plug back into
place, plug the ventilator connector
back on and screw the cover back on.
15.b To access the evaporator casing without recovering the gas of the A/C unit:
1. Remove the 6 fastening screws of
the unit cover, lift the cover and
unplug the ventilator connector.
Remove the 4 condenser fastening
screws (circled in blue)
2. Remove the 6 fastening screws of
the evaporator casing cover. Lift
slightly the front of the condenser,
bring the cover forward to free the
condenser supports (circled in green),
and slide the cover to the side
3. You can access to the thermostat
(circled in red), to the blower and to
the evaporator.
4. Once the repair is completed,
assemble and screw all the parts back
on.