Mechanical faults on pumps
Fault
Possible cause/ recognizability of fault
Remedy
Lubricant volume on one or more lubrication
points deviates from projected values
○
Wrong setting of pause time or number of me-
tering device cycles
○
Wrong cross-porting of outlets on the SSV me-
tering device
○
Check and, if necessary, correct
pause time settings and metering device cycles
○
Check and, if necessary, correct
cross-porting of outlets
Pump is permanently on/
Pump does not switch off
○
Indicator pin on metering device does not move
within switching distance of proximity switch or
indicator pin is not positioned centrically in front
of proximity switch
○
Check position and distance of indicator pin
(distance < 0.5 mm) and correct, if necessary
If the fault cannot be determined and remedied, please contact our Customer Service.