4. Technical data
4.1 General technical data
Pump variant
24 V DC
120 V AC 60 Hz
230 V AC 50 Hz
Admissible operating temperature
-25 °C to 70 °C
Operating pressure
120 bar max.
Installation position
vertical (max. deviation± 5 °)
Lubrication points
max. 18
sound pressure level
< 70 dB (A)
Reservoir size
1 litre
Filling
via hydraulic lubrication fitting R 1/4
Weight of empty pump
approx. 6 kg
Lubricants
2)
Lubricating greases NLGI II and NLGI III
1)
/ fluid greases NLGI 00, 000
Output of pump element
2
approx. 0.2 ccm (per stroke)
approx. 1.0 ccm (per minute)
Output of metering device
approx. 0.2 ccm (per cycle)
Maximum pump run time
30 minutes
1)
NLGI III lubricants may be supplied under certain operating conditions only. Therefore the lubricant's supply characteristics
has to be clariefied with SKF in advance.
2)
Observe the references given in chapter 4.6 and 4.7.
Temperature [°C]:
-25 °C
-20 °C
+25 °C
024 V DC
Speed [rpm]
5.3 - 6.0
6.2 - 7.3
7.3 - 8.3
120 V AC
Speed [rpm]
5.9-6,9
8.3
8.5 - 9.0
230 V AC
Speed [rpm]
2.5 - 5, 6
6.5 - 6.8
6.9 - 7.1
The indicated rotational speeds depend on counterpressure and temperature. In principle the following applies:
The higher the counterpressure and the lower the temperature, the lower is the rotational speed.