background image

Adjusting the parameters 

 

Page 17 

 

EN

10.1

 

General 

The optimum adjustment of the MQL system 
L

UBRI

L

EAN

®

 Vario depends on several factors 

such as the applicable primary pressure, length 
of the aerosol transport lines, type and size of 
the tool, cross-section of the cooling channel as 
well as the processing procedure. For this 
reason it is not possible here to specify absolute 
adjustment parameters for the particular 
processing situations. 
 
The adjustment parameters illustrated in Fig. 6 
are approximate values and should provide you 
with an initial orientation for adjusting the MQL 
system L

UBRI

L

EAN

®

 Vario for your particular 

application. 
 
We recommend that you determine and 
optimise the necessary adjustment values for 
your particular application by performing test 
runs so that you can achieve the best results for 
your processing procedure. 
 
If the machine has been idle for extended 
periods or a tool has been replaced, this can 
result in temporary discontinuities in the aerosol 
supply to the lubrication point and the 
generation of oil mist. The supply of lubricant 
will re-stabilise during operation and possible oil 
mist that has been generated will disappear. 
 
 
 

10.2

 

Effect of primary pressure 

The MQL system L

UBRI

L

EAN

®

 Vario obtains the 

energy necessary for generating aerosol from 
the compressed air supplied to the system. 
 
The system is functional at least 6 bar of primary 
pressure and able to generate an aerosol 
suitable for most lubricating tasks.  
 
The full output of the system is, however, only 
possible with a primary pressure of 8 bar. 
 
 

10.3

 

Procedure for adjusting 
parameters 

The following indications should help you 
determine the correct adjustments for the MQL 
system and your particular application. 
 
1.

 

Put the MQL system L

UBRI

L

EAN

®

 Vario into 

operation by opening the main air valve. 

 
 
 
 
 
 
 
 
 

2.

 

Set the air valve to 6 bar and the lubricant 
flow rate to 100 %. With the spindle idle, 
check whether the aerosol is able to flow 
unimpeded through the channel system of 
the machine tool. This is easiest to 
recognise if the tool from the tool-receiving 
socket is removed. The aerosol must 
visibly discharge from the channel system. 

 
3.

 

Put the tool back into the tool-receiving 
socket and hold an oil-free component 
surface approximately 1 - 3 mm below the 
tool on the discharge channel. If no 
lubricant film collects on the component 
surface, there is a malfunction in the 
channel system of the tool. Check the tool 
and tool-receiving socket. 

 
4.

 

To determine the amount of lubricant that 
has been transported in the case of a 
rotating tool, spread a smooth and oil free 
panel on the machine table. Next, move 
the rotating tool until it is approximately 
1 - 3 mm above the panel.  

 

10 Adjusting the parameters 

Содержание LUBRILEAN Vario

Страница 1: ...LUBRILEAN Vario Minimum quantity lubrication system for internal lubrication Operating instructions Version 2...

Страница 2: ......

Страница 3: ...m of action 10 8 3 Structure of the system 12 8 4 Optical fill level display 12 8 5 Electrical fill level indicator 12 8 6 Display and setting of the lubricant flow rate 13 9 Assembly 14 9 1 Connector...

Страница 4: ...directive 98 37 EU must only be used in reference to the EU directive 97 23 EU pertaining to pressure devices only properly and according to the indications contained in the documentation Here the fo...

Страница 5: ...ve 67 548 EU Article 2 Paragraph 2 require agreement and the expressed written consent of SKF LUBRICATION SYSTEMS GERMANY AG to pour these substances into SKF products transport them and or distribute...

Страница 6: ...ting instructions and the local safety regulations All types of fire in the form of open flames sparks cigarette embers etc must not be anywhere near the directed spray or in rooms where the aerosol c...

Страница 7: ...personnel who have first disconnected the power and ensured the system is voltage free CAUTION DANGER OF DEATH Working on MQL systems that have not been disconnected from the power supply and are not...

Страница 8: ...uned to the high demands of the MQL technology applied here Therefore only lubricants offered by SKF must be used If you would like to use other lubricants you should first consult SKF The lubricants...

Страница 9: ...acid ester with additives Viscosity 47 mm s at 40 C Density 0 92 g cm at 20 C Universal applications LubriFluid F100 Synthetic polyol ester with natural fatty oil derivative base with anti oxidizing...

Страница 10: ...on of the lubricant droplet generates a very homogenous aerosol with a very small droplet size Due to the small size the lubricant droplets are very light which therefore requires a very low inertia T...

Страница 11: ...erf llt overfille d 120 40 bar 2 140 20 psi 100 6 60 4 80 40 10 8 20 2 bar 8 140 10 120 psi 60 4 100 6 80 P01 V01 V02 Q01 V03 Q02 V04 S01 50 20 10 30 40 90 70 60 80 100 V05 B01 245 10 0 21 25 191 5 20...

Страница 12: ...justable To open the valve pull the rotary knob out in the direction away from the system hold it in this position and then turn it clockwise To close it pull the knob and turn it anti clockwise The c...

Страница 13: ...is attached to the side of the aerosol container The level of the float in the glass pipe shows the flow rate of the particular lubricant Note The float is always read using its horizontal diameter Fi...

Страница 14: ...tlets no 1 Fig 1 which are set up as a plug and socket connection for hoses with an outside diameter of 12 mm Only pneumatic hoses may be used that are suited for an operating pressure of at least 10...

Страница 15: ...receiving socket The aerosol lines should be exposed to as few vibrations and oscillations as possible The aerosol routing should exhibit a continuous incline towards the machine Downward bends should...

Страница 16: ...valves can be removed 9 3 Compressed air connection Before connecting your MQL system to the compressed air supply make sure that the main air valve is closed The MQL system LUBRILEAN Vario is equippe...

Страница 17: ...gy necessary for generating aerosol from the compressed air supplied to the system The system is functional at least 6 bar of primary pressure and able to generate an aerosol suitable for most lubrica...

Страница 18: ...r of the tool visible on the panel 6 Adapt the aerosol mixture and the aerosol quantity to the processing procedure until the processing result satisfies your requirements We recommend that you make a...

Страница 19: ...equires little maintenance To ensure perfect functioning and avoid hazards from the outset you should however regularly check all connections as well as functions All advanced work beyond what is desc...

Страница 20: ...ase read the following section about draining the lubricant Do not mix different lubricants with each other if there is no explicit approval from SKF Otherwise damages may result and a cumbersome inte...

Страница 21: ...he interior of the MQL system yourself The disassembly of the lubrication container or other parts of the MQL system is not permitted and renders all warranty claims null and void Moreover this can re...

Страница 22: ...f lubricants not approved by SKF Use only lubricants approved by SKF The system produces no aerosol The system is defective or maladjusted Contact our service department The aerosol transport lines ar...

Страница 23: ...r minimal quantity lubrication The tool has an unsuitable intake and a very small cooling channel Use only the tools suited for minimal quantity lubrication No aerosol is applied to the tool For small...

Страница 24: ...ivation and direct contact It is recommended that the lubricant be drained for extended shutdown periods 14 2 Permanent shutdown If you want to shut down the MQL system permanently please observe the...

Страница 25: ...422 W 235 D 250 Enlarging the casing dimensions with protruding attachments without connections mm H 422 W 235 D 250 Weight kg 9 8 Compressed air Max primary pressure bar 10 Min primary pressure bar...

Страница 26: ...Technical Data Page 26 EN...

Страница 27: ...Notes EN...

Страница 28: ...Notes EN...

Страница 29: ...Notes EN...

Страница 30: ...Notes EN...

Страница 31: ......

Страница 32: ...Systems Germany AG Motzener Stra e 35 37 12277 Berlin Postfach 970444 12704 Berlin Telefon 49 30 7 20 02 0 Fax 49 30 7 20 02 111 E Mail lubrication germany skf com WWW www skf com schmierung 951 130 2...

Отзывы: