Quick Setup/Installation Guide for Lubrication Monitor Controller LMC 301
951-150-029-EN
23
Fig 24
Remote Manual Lube
Input Type
[ <<no
rmally closed>> <<normally open>><<disabled>>]
Input No.
[1,05 DI
Setting the level monitoring
and filling
Motor Protection
Motor Protection Type
[ << disabled >> << normally closed>>
<< normally open>>
Input No.
[ 1, 04 ] DI
Additional monitoring
Set Params to Default
Set Params to Default?
Continue?
Note!
Additional buttons
in transducer setting
Relief Settings
Zone Relief Time
[ 00:03] s
Pump Relief Time
[ 00:03] s
Note!
Menu only upon activation of the
3/2 zone valve
(System Settings => type of zone valves)
Inputs
Input LL Typ
[
<< disabled>> << transducer 1-6V >> << transducer 4-20 mA >>
<<transducer 0-20mA >><<transducer 2-10V >> <<transducer 0-10V>>
<<normally closed>> <<normally open>>]
Eingang No. LL Typ
[ 1,03 ] DI
Minimal Valve
[000] %
Maximal Valve
[000] %
Full Valve
[000] %
Empty Valve
[000] %
Critical Valve
[000] %
Note!
Additional buttons for transducer setting
Note!
The menu items are dependent on the fill level adjustment,
Menu Monitoring
Note!
Menu Alarm / inputs / times only with
activated monitoring
Temperature Control
Internal Sensor
Externalr Sensor
Temperature Limits
Internal Sensor
InternalSensor
[ << disabledt>><< enabled>>]
IO Board
[ 1 ]
Temperature Limits
Over temperature
[ 180,0 ] F
Under temperature
[ 14,0 ] F
External Sensor
Sensortyp
[
<< disabled>> << transducer 1-6V >> << transducer 4-20 mA >>
<<transducer 0-20mA >><<transducer 2-10V >> <<transducer 0-10V>>
<<normally closed>> <<normally open>>]
Input
[ 1,02 ] AI
Minimal Valve
[ 0000 ] PSI
Maximal Valve
[ 0000 ] PSI
Note!
Additional buttons for transducer setting
Restore Fact. Set.
Restore Fact. Set?
Continue?
Login settings
User settings
Device settings
Pump 1 Timings
System configuration
Information
Main Menu
Login settings
Enter Password
Set PW local admin
Set PW Supervisor
Enter Password
Please enter Password
to continue
0000
Password correct
You are logged in
as Supervisor
Login settings
Login settings
System configuration
Amount of pumps
Pump 1 settings
Set Params to Default
Restore Fact. Set.
Amount of pumps
Amount of pumps
[
<< 1 pump >> << 2 pump>> << 3 pump >>]
System Type
System Type
[
<< Single Line >> << Progressive >>
<< Dual Line >>
]
Zone
[ 3 Zone ]
Zone valve type
[
<<EMU3 >> << EMU2 >> << MA/MP >>
<<
DU1 self co ><< 3/2 Way Valve>> ]
Pump Settings
System Type
Lube control
Relief Settings
Filling/Low Level
Motor Protection
Temperature Control
Pump 1 settings
Pump settings
Zone 1 Settings
Lube Control
Pump Output
Sensor at Pump Set.
Remote Manual Lube
Pump Output
Output Type
[ <<normally closed>> <<normally open>> << disabled>>
Output No.
[ 1,01 ] O
Output Type3nd Sel
[ <<normally closed>> <<normally open>> << disabled>>
Output No. 2nd Sel
[ 1,01 ] O
Lubricating settings
Sensor at Pump Set.
Sensor Type
[
<< disabled>> << transducer 1-6V >>
<< transducer 4-20 mA >> transducer 0-20mA >>
<<transducer 2-10V >> <<transducer 0-10V>>
[ <<normally closed>> <<normally open>>]
Input No.
[1,02] DI
Minimal Valve
[000] PSI
Maximal Valve
[000] PSI
Maximal System Valve
[000] PSI
Filling/Low Level
Monitoring
Alarm
Inputs
Timings
Monitoring
Filling Monitoring type
[ << Low Level Detection>> << Auto Filling>> <<disabled>>
Lube Limited By
[ << Lube Cycles>> << Pump time>> << disabled >>
Alarm
Output Type
[ << normally closed>>
<< normally open>> << disabled>>
Output No
[ 1,02 ] O
Timings
Filling Timeout
[ 00: 00: 00 ]
Detection LL Time [ 10]
System setting Dual Line
Deining the zone valves
6.5 Menu navigation for system coniguration -
Dual Line settings with Supervisor password
Supervisor password
factory setting:
2020