Quick Setup/Installation Guide for Lubrication Monitor Controller LMC 301
951-150-029-EN
20
Fig. 21
6.2 Menu navigation for system coniguration -
Single Line zone settings
Login settings
Cycle Control
Timings
Release/Counter
Lube Load
Timings
Control Mode
[ << time controlled >> << Counder ctrld >> ]
Normal Cycle Time
[0000: 00: 00]
Heavy Cycle Time
[0000: 00: 00]
Release/Counter
Input Type
[ << normally closed >> << normally open >> << disabled >> ]
Input No.
[ 1,06 ] DI
Lube Loade
Input Type
[ << normally open >> << normally closed >> << disabled >> ]
Input No.
[ 1,07 ] DI
Lube Control
Vent Valve
Press. Sensor at EOL
Flow Sensor
Lube Control Time
Vent Valve
Output Type
[ << normally open> <<normally closed >> << disabled>> ]
Output No.
[ 1,03 ] 0
Holding time
[ 00: 00 ] s
Press. Sensor at EOL
Sensor Type
[
<< disabled >> << transducer 1-6V >>
<< transducer 4-20 mA >> << transducer 0-20mA >>
<< transducer 2-10V >> << transducer 0-10V >>
<< normally open >> << normally closed >> ]
Input No.
[ 1,01 ] AI
Minimal Valve
[ 0000 ] PSI
Maximal Valve
[ 0000 ] PSI
Deploy Valve
[ 0000 ] PSI
Vent Valve
[ 0000 ] PSI
Lube Control Time
Monitoring Time
[00: 00: 00]
Set Params to Default
Set Params to Default?
Continue?
Flow Sensor
Amnt of Flow Sensor
[ 1]
Input No.1 Typ
[ << normally open>> << normally closed>>
<< disabled>> ]
Eingang Nr. 1
[ 1,08 ] DI
Amount of pumps
Amount of pumps
[
<< 1 pump >> << 2 pumps>> << 3 pmps >>]
Login settings
User settings
Device settings
Pump 1 Timings
System configuration
Informationen
Main Menu
System configuration
Amount of pumps
Pump 1settings
Set Params to Default
Pump 1 settings
Pump settings
Zone 1 Settings
Zone 2 Settings
Zone 3 Settings
Zone 1 Settings
Cycle Control
Lube Control
Post Sprayer
Alarm
Login settings
Enter Password
Set PW local admin
Set PW Supervisor
Enter Password
Please Enter Password
to Continue
0000
Password correct
Your locked an as
Subvisor
Login settings
Cycle settings Lubrication intervals
Lubrication timings
Kind of the control
Lubrication time interval
Functionality of her release/-
counter
Functionality of her zone
control and allocation
Zone cycle settings
Control and allocation of the
vent valve
Functionality and allocation of
the pressure sensors
(End of line)
Post Sprayer
Output Type
[ << nomally open >> << normally closed >> << dsabled>> ]
Output No.
[ 1,04 ] 0
Post Spray Time
[ 00: 00 ] s
Alarm
Output Type
[ << nomally open >> << normally closed >> << dsabled>> ]
Output No.
[ 1,06 ] 0
Monitoring and allocation of
the lubrication distributor
Monitoring and allocation of
the lubrication distributor
Note!
Additional buttons for transducer setting