Quick Setup/Installation Guide for Lubrication Monitor Controller LMC 301
951-150-029-EN
16
5.3 Coniguration of several IO boards to master slaves
Chapter 4.8 describes the IOPCB communi-
cation connection between an IO master and
an IO slave.
To connect two boards with each other, the
customer must prepare an adapter cable.
The cable must be shielded.
The plugs required for the adapter cable are
available on the respective board.
In the following please find further notes re-
garding the connection of the adapter cable.
SKF takes a separate voltage supply for each
board as given.
o SKF takes a separate voltage supply for
each board as given.
o The PE connection (ground) must be sepa-
rate for each board. Connection is made on
the respective board, see page 11, Fig. 9.
o The maximum admissible connected load of
each board is 3 A.
o In case of different potential-free outputs
make sure to use an adequate connection
line and a corresponding connection dia-
meter, see chapter 4.7.3.
o For each connection line the customer must
provide a correspondingly designed back-
up fuse.
ON
1 2 3 4
ON
1 2 3 4
ON
1 2 3 4
Connection Adapter Cable
Sock
et 1 to Socket 1
Socket 2 to Socket 2
Socket 3 to Socket 3
Socket 4 to Socket 4
LMC 301
Master
LMC 301
Slave 1
LMC 301
Slave 2
Wiring and Setting Master/Slave, Fig. 17
Caution!
When preparing the adapter cable use a shielded cable.
Adapterkabel
Master Board
Slave Board
Slave Board
LMC 301 Versions
Master Order No.
24 VDC
086500
100 to 240
VAC
086501
Slave
Order Number
24 VDC I/O
086502
100 to 240 VAC I/O 086503