Installation Instructions
Pump P 215
810-55192-1
Page 30 / 45
Rev. 012
2018/11/30
8.5. Filling the reservoir
WARNING
Risk of hand injuries caused by the stirring paddle
Fill lubricant via the lid only when the pump is not moving. Never
reach into the reservoir while the pump is running.
ATTENTION
Risk of central lubrication system faults
•
When filling, ensure that no contamination enters the reservoir.
•
The ultrasonic sensor must not come into contact with the lubricant.
•
The distance between the lubricant and the ultrasonic sensor should total at least
60 mm.
Filling via the reservoir lid
➢
Switch off the pump.
➢
Open the reservoir lid (1).
➢
Fill in lubricant.
➢
Close the reservoir lid (1).
➢
Switch on the pump.
Filling via the filling adapter
Automatic filling:
The filling pump is controlled by the high-level
or low-level signal on the pump.
Manual filling:
Have the filling procedure observed by a
second person.
➢
Switch on the filling pump.
➢
Fill the reservoir.
➢
Switch off the filling pump.