
Installation Instructions
Pump P 215
810-55192-1
Page 26 / 45
Rev. 012
2018/11/30
Working method:
The gear (5) reduces the motor speed (6)
to the necessary speed of the eccentric
shaft (7).
The eccentric shaft (7) drives the pump
elements (3) and the stirring paddle.
The stirring paddle homogenizes and
ventilates the lubricant and pushes it in the
direction of the suction boreholes of the
pump elements (3).
The pump elements (3) convey the
lubricant by the movement of the pistons.
It is distinguished between the suction
phase (suction of lubricant out of the
reservoir) and the pressure phase (supply
of lubricant into the lubrication line).
If necessary, a sensor determines the
reservoir filling-level (high-level or low-level
signal).
8.
Installation and commissioning
8.1. Important note on the installation of the pump elements
Pump elements are factory-set to minimum
flow rate in order to improve the suction
behaviour (minimum space of air in the
pump element).
After commissioning, the pump elements
must be set to the required flow rate.
For installation of the individual pump
elements, see schematic on the right.
1
2
4
3
6
5
8
11
7
9
3
10
12
7
13
14
15
3
Содержание Lincoln 215-M049
Страница 1: ...Installation Instructions Pump P 215 810 55192 1 Page 1 45 Rev 012 2018 11 30 P 215...
Страница 23: ...Installation Instructions Pump P 215 810 55192 1 Page 23 45 Rev 012 2018 11 30...
Страница 43: ...Installation Instructions Pump P 215 810 55192 1 Page 43 45 Rev 012 2018 11 30 M100 M049 100XY...