Installing the Machine Condition Transmitter
Analyzing MCT Readings
4- 6
SKF Machine Condition Transmitter
User
Manual
Figure 4 - 32.
MCT CMSS540 Eddy Probe Interfacing.
Analyzing MCT Readings
Unlike other SKF Reliability Systems' analyzing products
that use digital signal processing, MCT modules use
analog signal processing techniques, so be careful when
comparing results with digital instruments. For
enveloped acceleration (gE) applications, the filter ranges
in the Microlog and Multilog are equal, but the filter