CMSS500 Series Monitor
Alert and Danger Alarm Delays Adjustment
SKF Machine Condition Transmitter
3- 5
User Manual
Setting Jumper
Configuration
Alert Time Delay
E1
0.1
sec
E2
1
sec
E3*
3 sec /
*factory preset
E4
6
sec
E5
10
sec
Danger Time Delay
E6
0.1
sec
E7
1
sec
E8*
3 sec /
*factory preset
E9
6
sec
E10
10
sec
Latching / Non-
latching Alarms
E11*
Open: Alert Non-latching /
*factory preset
Closed: Alert Latching
E12*
Open: Danger Non-latching /
*factory preset
Closed: Danger Latching
Trip Multiply factor
E13*
Open: factor 2x
/*factory preset
Closed: factor 3x
Table 3 - 1.
Monitor Jumper Options.