![SKF 24-2583-2526 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/skf/24-2583-2526/24-2583-2526_operating-instructions-manual_1287148045.webp)
11
EN
11. Malfunctions
10
12
- 45 -
951-180-087-EN
Version 01
11.
Malfunctions, causes, and remedies
12.
Repairs
IMPORTANT NOTE
Dismantl
ing of a pulse generator of series
SP/SFE 3003 or SP/SFE3006 into indi-
vidual components is prohibited and voids
any claims.
Malfunction Cause
Remedy
No
Signal
Pulse generator 24-2583-2526
:
o Cable socket is not installed correctly
o Pigtails in the cable socket are not con-
nected or are connected incorrectly
o Customer did not/did not correctly
connect pigtails.
o Pulse generator is defective
Pulse generator 24-2583-2528
:
o Customer did not/did not correctly
connect pigtails.
o Pulse generator is defective
See Chapter 6.3
• Remount the cable socket and
tighten with a mounting screw.
• Check the pigtails and connect
if necessary.
• Check/correct customer's con-
nection of pigtails.
• Replace the entire pulse
generator.
• Check for correct connec-
tion of pigtails and connect if
necessary.
• Replace the entire pulse
generator.