4
EN
4. Technical data
- 33 -
951-180-087-EN
Version 01
P
ulse generator 24-2583-2528
Protection class of the pulse generator
24-2583-2528
Protection class of the sensor
2G IIC T6 Gb
II 2G Ex ia IIC T6...T1 Gb
3) A pulse comprises the opening or closing of the
reed contact.
4) A cable length of 10 m is taken into account.
5) See the sensor's EC type examination certificate for
the relationship between the type of connected circuit,
the maximum permissible ambient temperature, the
surface temperature, and the effective internal reac-
tances.
The number of the type examination certificate is
entered on the sensor type plate.
(Location of motor type plate - See Figure 1)
1D IIIC T135°C Da
II 1D Ex ia IIIC T135° Da
-20 ... +70°C
-25 ... 85°C (-13 ... 185°F)
5
)
Specifications of the sensor
Operating pressure
4 to 350 bar
Volume/pulse
3
)
0,64 cm
3
Electrical data for the sensor
Switching element function
NAMUR NC contact
Nominal distance S
n
1,5 mm, flush mountable
Secured sensing distance S
a
0 to 1.22 mm
Rated voltage U
o
8.2 V DC
Max. voltage U
i
16 V DC
Max. current I
i
25 mA
Max. power P
i
64 mW
Power consumption
-Measuring plate not detected
-Measuring plate detected
≥ 3 mA
≤ 1 mA
Capacitance C
i
50 nF
4
)
Inductance L
i
60 µH
4
)
Power lead
PVC, 15 m, 2 x 0,34 mm
2
maximum permissible ambient temperature T
amb
See note
5
)