![SKF 24-2583-2526 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/skf/24-2583-2526/24-2583-2526_operating-instructions-manual_1287148032.webp)
EN
4. Technic
al data
- 32 -
951-180-087-EN
Version 01
4. Technical data
G
eneral characteristics of pulse generators
Mounting position
Any
Ambient
temperature range -20 bis + 70 °C
Lubricant
temperature range -15 to +70 °C
Weight
1,1 kg
Ground terminal
1
)
M4
Hydraulic system
Pressure loss
Approx. 4 bar
Lubricant
Mineral oils, synthetic and
environmentally friendly oils, greases based
on mineral oil
Operating viscosity
> 12 mm²/s
Worked penetration > 260 1/10 mm
Volumetric flow range 0,1 to 50 cm
3
/min
1) The customer must determine the required
cross-section and the quality and length of
the grounding cable to be connected to the
pulse generator according to the particular
operating conditions.
A customer-supplied circuit breaker
must be installed at the factory.
Pulse generator 24-2583-2526
General
Hydraulic
Operating pressure
4 to 600 bar
Volume/pulse
2
)
0,58 cm
3
Electrical
Contact type
Reed contact
Max. voltage U
i
30 V DC
Max. current I
i
100 mA
Capacitance C
i
1 nF
Inductance L
i
5µH
Max. power P
i
1W
Connection type
DIN 43650-A plug
Plug
3 +PE
Max. conductor cross-section
of the cable to be connected
2 x 0.75 mm
2
2) A pulse comprises the opening or closing of the reed contact.