Battery and Charging Notes and Cautions
• Do not operate pump from or charge pump with charger in hazardous atmospheres.
• Use only the SKC-approved battery pack (Cat. No. P76303) and charging cable supplied in Cat. No. 220-300. Use of an
unapproved battery and/or charging cable could damage the pump and will void any warranty.
• Turn off pump before removing the battery pack.
• Tampering with the battery pack (opening, disassembling, short circuiting, crushing, or exposing the battery pack to
fi
re or
temperatures in excess of 212 F [100 C]) voids any warranty.
• Protect sample pump from rain and extended direct exposure to sun when in use outdoors
• Allow pump to equilibrate when moving it from one temperature extreme to another.
• Failure to follow warnings and cautions voids any warranty.
• Substitution of components may impair intrinsic safety. La substitution de composants peut compromettre la Sécurité Intrinsèque.
• To prevent ignition of hazardous atmosphere, batteries must only be charged (removed and replaced) in an area to be known
nonhazardous. A
fi
n de prévenir l’in
fl
ammation d’atmosphères dangereuses, ne changer les batteries que dans des emplacements
désignés non dangereux.
• Maximum charge input voltage U
m
= 5.5 VDC.
• The battery used in this device may present a risk of
fi
re or explosion when heated above 212 F (100 C) or incinerated. Replace
battery with SKC Battery Pack Cat. No. P76303 only. Use of another battery may present a risk of
fi
re or explosion.
Turning Pump Power On/Off
Turn on:
Press the Power On/O
ff
bu
tt
on on the top of the pump
(Figure 1)
; the screen will light.
Turn o
ff
:
Press the Power On/O
ff
bu
tt
on on the top of a non-running pump
(Figure 1)
; the screen will go dark. The pump will automatically
power o
ff
after
fi
ve minutes of inactivity.
Interpreting the Display
FPO
Time
(12 or 24-hr display)
Date
(3 format options)
Battery status icon
(charge remaining)
Flow rate (ml/min
constant fl ow or inH2O
constant pressure)
Calibration correction
applied
Screen
locked to
prevent
accidental
tap
errors or
tampering
Accumulated run time
Scrolling display of
accumulated sample
volume (L), ambient
temperature (F or C),
atmospheric pressure
(mbar, inHg, mmHg),
and back pressure
(inH2O)
Constant display at the top of every screen
Displays while pump is running.