42
Problem
Possible Cause
Solution
E1
No speed- signal
1. Check the ASSEMBLY INSTRUCTIONS and make sure that all computer plugs etc. are con-
nected correctly and FIRMLY.
2. Check the resistance of the appliance and make sure that it was set-up correctly.
A problem can appear if the motor tries to adjust the resistance - it makes loud sounds then.
This can be a sign that the motor was damaged already by fault. Remove the fault and check
the motor.
3. Motor problems
a. Symptoms can be that the motor makes unusually loud sounds.
Then, the toothed wheels don‘t interlock correctly.
Reset the resistance and try it again.
b. If the motor does not move any more, check as described above.
4. If you don’t succeed, replace the motor
E2
The computer cannot
connect with the IC
chip.
Separate the adapter and/or, remove the batteries.
Connect the adapter and/or the batteries. This will restart the IC chip and will help to connect the
computer with the IC chip.
Remove the IC chip and then reset it.
If resetting the chip doesn‘t help, replace the IC chip.
E3
During the analysis of
the body fat, there is no
heart recognition in the
first 8 seconds.
Check whether you held the handles firmly with both hands.
E5
Auto voltage (Numbers)
is not separate from the
zero point
1. Check the resistance of the appliance and make sure that it was set-up correctly. A problem can
appear if the motor tries to adjust the resistance - it makes loud sounds then. This can be a sign
that the motor was damaged already by fault. Remove the fault and check the motor.
2. Motor problems
a. Symptoms can be that the motor makes unusually loud sounds.
Then, the toothed wheels don‘t interlock correctly.
Reset the resistance and try it again.
b. If the motor does not move any more, check as described above.
3. If the above solutions do not help, replace the motor.
No pulse signal or
wrong pulse signal
The computer doesn‘t
receive any pulse signal
Check whether the hand pulse plugs are attached tightly.
The computer receives
a weak or interrupted
signal
1. The hand pulse sensors don‘t work correctly if your skin is extremely dry. Moisten your hands
and try it again.
2. The hand pulse sensors must be held tightly. If your hands move during the training, the
computer will only receive an interrupted signal. Don‘t move your hands and hold the handles
tightly. If you move your hands, wait for few seconds, so that the computer can collect your data
again and show.
3. Clean the sensors in order to guarantee a good contact.
4. Remove the sensors, in order to check, whether the connections are correct.
5.
If the problem is not fixed even after trying above solution, please contact your dealer.
The computer is
defective
Contact your dealer and replace the computer.
The LCD screen
shows nothing
You have the wrong
adapter or the wrong-
batteries.
Check whether the adapter and battery specifications are correct in accordance with instruction
manual.
The main switch is out.
Check whether the main switch is switched on and actually supplies the power.
The adapter is not
plugged in.
Check whether the adapter is connected correctly to the electricity point and also to the computer.
The batteries are
missing.
The batteries were
placed incorrectly.
Check whether batteries were placed.
Check, whether the batteries are placed correctly and with the right polarity (+ / -).
The computer is de-
fective
Contact your dealer and replace the computer.
FAULT DIAGNOSIS
Содержание JUPITER Series
Страница 1: ...Art Nr SF 1010 rot SF 1010GN grün ...
Страница 4: ...4 CHECKLISTE ...
Страница 5: ...5 DE Schritt 1 AUFBAUANLEITUNG ...
Страница 26: ...26 CHECKLIST ...
Страница 27: ...27 GB Step 1 ASSEMBLY INSTRUCTION MANUAL ...
Страница 48: ...48 CHECK LIST ...
Страница 49: ...49 FR 1ère étape INSTRUCTIONS D ASSEMBLAGE ...
Страница 68: ...2015 01 30 ...