E3
Demand Dose Application
high water
alarm fl oat
(recommended)
redundant
off fl oat
(recommended)
l
ag (duplex
only)
high water
alarm
start
stop
0
Timed Dose Application
high water
alarm fl oat
(recommended)
redundant off
fl oat
(recommended)
high water
alarm
timer
enable
timer
override
redundant
off
0
Float Switch Positioning
CAUTION!
If the C-Level™ sensor or fl oat
switches are not mounted and
connected correctly, the pumps
and alarm will not operate
properly.
3.5”
(9 cm)
C-Level™ Sensor Positioning
Keep vent above water level.
hose
clamp
4 inch (10.2 cm)
minimum set level
0 inch (0 cm) liquid
level measured from
approximately this point
1 inch (2.5 cm)
minimum from bottom
of tank or from sludge
hose
clamp
Stow excess tube using a
cable tie.
Caution:
Do not overtighten
and pinch vent tube.
Do not use the hose clamp
to attach the vent tube.
Doing so will cause sensor
to fail.
cable
tie
C-Level
™
Sensor and Float Switch Installation