Document NO.: RD-529-39-001
Version: A
- 6 -
Diagram 4
Diagram 5
Installation:
•
Fix the one CR17450 batteries to each battery box of the
smoke alarm.
·
According to the
“Wireless function description”
Section to operate the smoke alarm. Ensure the wireless
function is ok.
·
Then press the bracket on the installation position, mark
installation hole of bracket with pencil.
·
Bore two installation hole on the sign with electric drill.
Make diameter of holes is 5mm, Strike the two plastic
plugs into holes with hammer.
·
Attach the bracket to the plastic plugs and fix tightly the
screws (3*25mm) into the plastic plugs. (refer to
Diagram 6).
·
Fit the alarm on the bracket and turn the alarm body
clockwise, until matching well on the bracket.
·
Test smoke alarm using test button. The sound pattern is 3
short and weak beeps, 1.5seconds pause, 3 short and week
beeps, 4.5seconds pause, repeat it, If continue testing , the
beeps will become louder. Then repeat it until release the
button.
·
If no sound, it indicates a defective alarm, you can refer to
“Trouble shooting” for solution or return to your retailer
during warranty.
·
If you have any questions on installation, you can contact
your retailer.
·
During testing, may the other smoke detector will alarm.
Once release the button, others will stop alarming in 1
minute. In such a way, you can check the wireless
function.
WARNING:
To prevent injury, this unit must be securely attached to the
ceiling in accordance with the installation instructions.