![Siterwell GS529 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/siterwell/gs529/gs529_user-manual_1285776003.webp)
Document NO.: RD-529-39-001
Version: A
- 3 -
NOTE: WEEKLY TESTING IS REQUIRED
LED indicators
This smoke alarm is equipped with red LED indicators.
Standby Condition
: The red LED will flash every 50
seconds to indicate that the smoke alarm is operating
properly.
Alarm Condition
: When the alarm detects products of
combustion and goes into alarm, the red LED will flash
rapidly (one flash per second). The rapid flashing LED and
pulsating alarm will continue until the air is cleared or the
test button is released.
Silence Condition:
The red LED will flash every 16 seconds
as long as the alarm is in Hush mode.
Low battery trouble indication:
An intermittent “chirp”
accompanied by a red LED flashing every 50 seconds
indicates a low battery, you may press the test button to
silence the trouble indication for 10 hours, but it will reset
automatically after 10 hours. During this condition the unit
will continue to operate normally and detect smoke and
sound an alarm. This action only temporarily silences the
chirp.
As the battery in this unit is replaceable. When Replace
the batteries. Make sure to use EVE CR17450 and install
them in the right order.
Fault indication:
This chirp will occur between the flash of
the red LED indicator light.
NOTE
:
When the unit chirps once every 50 seconds,
pressing the test button temporarily silences this warning
tone for 10 hours
,
Refer to “Trouble shooting” section for
solutions, if the fault signal reactivates,
you MUST replace
the unit with a new alarm at once
or contact you retailer
during warranty.
SMOKE SENSING CHAMBER OPERATION: The alarm
will “chirp” if any of the components in the smoke sensing
chamber fail. This chirp will occur between the flashes of the
red LED indicator light. (If the chirp occurs at the same time
as the red LED flashing, indicating a low battery
information).
Alarm silence (silence mode):
When the alarm sounds check for a fire first, After verifying
that it is not a fire the alarm can be silenced by pushing the
test button This will silence the alarm for approx 10 minutes.
The red LED will flash once every 16 seconds indicating the
smoke alarm is in the silence mode. Smoke alarms are
designed to minimize nuisance alarms, but combustion
particles from cooking may set off the alarm if the alarm is
located close to the cooking area. To minimize the
occurrence of false alarms, smoke alarms must be installed a
minimum of 10 feet(3 meters) from the nearest cooking
appliance. If you accidentally let some smoke into the alarm
cause alarm, you can open the doors and windows. Turn on
the fan blew it. The alarm will silence (test button) is
extremely useful in a kitchen area or other areas prone to
nuisance alarms. The silence feature is to be used only when
a known alarm condition, such as smoke from cooking
activates the alarm. The smoke alarm is desensitized by push
the alarm silence (silence mode) on the smoke alarm cover,
the alarm will silence to indicate that the alarm is in a
temporarily desensitized condition. The smoke alarm will
automatically reset after approximately 10 minutes, if after
this period, particles of combustion are still present, the
alarm will sound again. The alarm silencer (silence mode)
can be repeatedly until the air has been cleared of the
condition causing the alarm.
CAUTION:
Before using the alarm silence (silence),
identify the source of the smoke and be certain a safe
condition exists.
DANGER:
If the alarm sounds, and it is not being tested, it
means the unit is sensing smoke,
THE SOUND OF THE
ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND
ACTION.