background image

 

 

   

 

 

             

Document NO.: RD-529-39-001 

                                                                                                                        Version: A     

- 3 - 

NOTE: WEEKLY TESTING IS REQUIRED 

 

LED indicators 

This smoke alarm is equipped with red LED indicators. 

Standby  Condition

:  The  red  LED  will  flash  every  50 

seconds  to  indicate  that  the  smoke  alarm  is  operating 

properly. 

Alarm  Condition

:  When  the  alarm  detects  products  of 

combustion  and  goes  into  alarm,  the  red  LED  will  flash 

rapidly  (one  flash  per  second).  The  rapid  flashing  LED  and 

pulsating  alarm  will  continue  until  the  air  is  cleared  or  the 

test button is released. 

Silence Condition:

 The red LED will flash every 16 seconds 

as long as the alarm is in Hush mode. 

Low  battery  trouble  indication: 

An  intermittent  “chirp” 

accompanied  by  a  red  LED  flashing  every  50  seconds 

indicates  a  low  battery,  you  may  press  the  test  button  to 

silence  the  trouble  indication  for  10  hours,  but  it  will  reset 

automatically  after  10  hours.  During  this  condition  the  unit 

will  continue  to  operate  normally  and  detect  smoke  and 

sound  an  alarm.  This  action  only  temporarily  silences  the 

chirp. 

As the battery in this unit is replaceable. When Replace 

the  batteries.  Make  sure  to  use  EVE  CR17450  and  install 

them in the right order. 

Fault indication: 

This chirp will occur between the flash of 

the red LED indicator light. 

NOTE

:

  When  the  unit  chirps  once  every  50  seconds, 

pressing  the  test  button  temporarily  silences  this  warning 
tone  for  10  hours

Refer  to  “Trouble  shooting”  section  for 

solutions, if  the fault  signal  reactivates, 

you  MUST  replace 

the  unit  with  a  new  alarm  at  once 

or  contact  you  retailer 

during warranty.     
SMOKE  SENSING  CHAMBER  OPERATION:  The  alarm 
will  “chirp”  if  any  of  the  components in  the  smoke  sensing 

chamber fail. This chirp will occur between the flashes of the 

red LED indicator light. (If the chirp occurs at the same time 

as  the  red  LED  flashing,  indicating  a  low  battery 

information). 

Alarm silence (silence mode): 

When the alarm sounds check for a fire first, After verifying 

that  it  is not  a fire the alarm can be silenced  by  pushing  the 

test button This will silence the alarm for approx 10 minutes. 

The red LED will flash once every 16 seconds indicating the 

smoke  alarm  is  in  the  silence  mode.  Smoke  alarms  are 

designed  to  minimize  nuisance  alarms,  but  combustion 

particles  from  cooking  may  set  off  the  alarm  if  the  alarm  is 

located  close  to  the  cooking  area.  To  minimize  the 

occurrence of false alarms, smoke alarms must be installed a 

minimum  of  10  feet(3  meters)  from  the  nearest  cooking 

appliance. If you accidentally let some smoke into the alarm 

cause  alarm,  you  can  open  the  doors  and  windows.  Turn  on 

the  fan  blew  it.  The  alarm  will  silence  (test  button)  is 

extremely  useful  in  a  kitchen  area  or  other  areas  prone  to 

nuisance alarms. The silence feature is to be used only when 

a  known  alarm  condition,  such  as  smoke  from  cooking 

activates the alarm. The smoke alarm is desensitized by push 

the  alarm  silence  (silence  mode)  on  the  smoke  alarm  cover, 

the  alarm  will  silence  to  indicate  that  the  alarm  is  in  a 

temporarily  desensitized  condition.  The  smoke  alarm  will 

automatically  reset  after  approximately  10  minutes,  if  after 

this  period,  particles  of  combustion  are  still  present,  the 

alarm  will  sound  again.  The  alarm  silencer  (silence  mode) 

can  be  repeatedly  until  the  air  has  been  cleared  of  the 

condition causing the alarm. 

CAUTION:

  Before  using  the  alarm  silence  (silence), 

identify  the  source  of  the  smoke  and  be  certain  a  safe 

condition exists. 

DANGER: 

If the alarm sounds, and it is not being tested, it 

means  the  unit  is  sensing  smoke, 

THE  SOUND  OF  THE 

ALARM  REQUIRES  YOUR  IMMEDIATE  ATTENTION  AND 

ACTION.     

 

 

 

 

 

 

 

 

 

 

 

 

Содержание GS529

Страница 1: ...n the ceiling inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end If there is a basement install a smoke alarm on the basement ceiling at the bottom of the stairwell Typical multi storey dwelling installation recommendations Install a minimum of one smoke alarm on each occupiable level of t...

Страница 2: ...se areas 3 Near air returns or heating and cooling supply vents Install at least 3 feet away from these areas The air could blow smoke away from the detector interrupting its alarm 4 In rooms where temperatures may fall below 0 or rise above 40 or in humidity higher than 93 These conditions will reduce battery life or cause a fault alarm 5 In extremely dusty dirty or insect infested areas influenc...

Страница 3: ...etween the flashes of the red LED indicator light If the chirp occurs at the same time as the red LED flashing indicating a low battery information Alarm silence silence mode When the alarm sounds check for a fire first After verifying that it is not a fire the alarm can be silenced by pushing the test button This will silence the alarm for approx 10 minutes The red LED will flash once every 16 se...

Страница 4: ...arm Trouble shooting DO NOT disconnect battery to quiet an unwanted alarm This will remove your protection Fan the air or open a window to remove smoke or dust Problem Cause and Remedy Smoke alarm does not sound when tested 1 Clean smoke alarm Please refer to the maintenance and cleaning section 2 If problems persist and the unit is still under warranty you can return to your retailer 3 If the uni...

Страница 5: ...or to those who may be incapable of safely evacuating the area unassisted RECOMMENDED LOCATIONS FOR ALARMS Locate the first alarm in the immediate area of the bedrooms Try to monitor the exit path as the bedrooms are usually farthest from the exit If more than one sleeping area exists locate additional alarms in each sleeping area Locate at least one alarm on every floor level Locate an alarm in e...

Страница 6: ...alarm on the bracket and turn the alarm body clockwise until matching well on the bracket Test smoke alarm using test button The sound pattern is 3 short and weak beeps 1 5seconds pause 3 short and week beeps 4 5seconds pause repeat it If continue testing the beeps will become louder Then repeat it until release the button If no sound it indicates a defective alarm you can refer to Trouble shootin...

Страница 7: ...In no case shall company be liable for any incidental or consequential damages for breach of this or any other warranty express or implied whatsoever The bad product can be mailed to the following address with a detail explanation of problem If after reviewing this manual you feel that your smoke alarm is defective in any way do not tamper with the unit Return it for servicing to SITERWELL ELECTRO...

Отзывы: