background image

4.2 Locations to avoid

For ensure the Combo Smoke/CO Alarm work 
properly and provide detection performance, do not 
install the device in the following places:
1. Near appliances or areas where normal 

combustion regularly occurs (kitchens, near 
furnaces, hot water heaters). Install at least 10 feet
away from these areas. Use specialized smoke alarm
device with unwanted alarm control for these 
areas.

2. In areas with high humidity, like bathrooms or 

areas near dishwashers or washing machines or 
directly above a sink. Install at least 10 feet away 
from these areas.

3. Avoid spraying aerosols near the device.
4. Next to a door or window, an extractor fan, air 

returns or heating and cooling supply vents. Install
at least 3 feet away from these areas. The air could
blow smoke away from the device, interrupting its 
alarm.

5. In rooms where temperatures may fall below 

0

 or rise above 40

, or in humidity higher than 

93%. These conditions will reduce battery life or 
cause a fault alarm.

6. In extremely dusty, dirty, or insect-infested areas,

particles may interfere with the device operation.

7. In the garage. Products of combustion are present

when you start your automobile.

8. In an enclosed space (for example in a cupboard 

or behind a curtain).

9. Where it can be obstructed (for example by 
furniture).
10. Less than 4 inch (10cm) from the peak of an “A”

frame type ceiling.

11. Near fluorescent lights. Electronic “noise” may 

cause nuisance alarms.

12. Place out of the reach of children. Under no 

circumstances should children be allowed to handle
the device.

4.3 Installation instructions

     

CAUTION! -

This device should be installed

by a competent person.

     

CAUTION! -

This Combo Smoke/CO alarm

MUST be installed on the matching bracket, 
otherwise the device won't work.

When choosing your installation locations, make 
sure you can hear the alarm from all sleeping areas. 
If you install only one device in your home, install 
the device near bedrooms, not in the basement or 
furnace room. 
1. Drilling two ф5.0mm holes in the ceiling or wall, 

the distance between two holes centre is 
70mm(2.76inch), then inserting two plastic plugs 
provided into the holes.

2. Attach the bracket to the plastic plugs and fix 

tightly the screws into the plastic plugs.
Do NOT over-tighten screws.

3. Install and rotate the alarm body on the bracket.
4. Test the device by using the TEST/SILENCE 

button. Ensure the device sound is alarm pattern.

             

5

 / 

14                      

GS883-A Instruction Manual Rev. G

Содержание GS883-A

Страница 1: ...e long beeps repeating every 1 5 seconds The ALARM indicator red will flash the same pattern The smoke alarm takes precedence when both smoke and carbon monoxide are present 1 1 What to do in case of fire 1 Do not panic stay calm 2 Leave the building as quickly as possible Touch doors to feel if they are hot do not open but use an alternate exit that is not hot Crawl along the floor and do not sto...

Страница 2: ...r the national Gas Emergency Service Provider if appropriate so that the source of carbon monoxide emissions can be identified and corrected Unless the reason for the alarm is obviously spurious do not use the fuel burning appliances again until they have been checked and cleared for use by a competent person according to national regulations If problems are identified during this inspection have ...

Страница 3: ...oke CO alarm will not promptly detect a fire or CO danger except in the area or room in which it is installed 6 This Combo Smoke CO alarm may not alert every household member every time The alarm horn is loud in order to alert individuals to a potential danger However there may be some circumstances where a household member may not hear the alarm i e outdoor or indoor noise sound sleepers drug or ...

Страница 4: ...d i e portable heaters or humidifiers 5 L o c a t e 1 0 f e e t a w a y f r o m a l appliances 6 Placing at eye level allows for optimum monitoring of the red and green indicator lights 7 Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the centre of the room places it closest to all points in the room Ceiling mounting is pre...

Страница 5: ...ombustion are present when you start your automobile 8 In an enclosed space for example in a cupboard or behind a curtain 9 Where it can be obstructed for example by furniture 10 Less than 4 inch 10cm from the peak of an A frame type ceiling 11 Near fluorescent lights Electronic noise may cause nuisance alarms 12 Place out of the reach of children Under no circumstances should children be allowed ...

Страница 6: ...m status of the smoke alarm or CO alarm 4 TEST SILENCE button The TEST SILENCE button is used to test the device and to silence the unit during a smoke alarm Press and hold to enable TEST function Or press to enable SILENCE function 5 Sounder The sounder is used to send out smoke alarm CO alarm warning and abnormal warning information 6 Power on switch The power on switch is used to power on the d...

Страница 7: ...sing the TEST SILENCE button it will come into a low battery voltage warning silence status for about 9 hours and FAULT indicator yellow continue to flash NOTE The silence feature of low battery voltage warning is temporary action to cancel warning sound effect you need to replace the device as possible as soon 6 Smoke alarm When the device detects a dangerous level of smoke the device will emit a...

Страница 8: ...If the CO alarm sounds and it is not being tested it means the unit is sensing a dangerous level of CO THE SOUND OF THE ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION 9 Human alarm sounds If the device enters into the status of smoke alarm or C O a l a r m t h e d e v i c e w i l l s t a r t i n a l o w e volume 85dB for around 10 seconds then emits a normal alarm volume 85dB This avoids start...

Страница 9: ...vice chirps twice with FAULT indicator yellow flashing twice every 40 seconds LOW BATTERY VOLTAGE SIGNAL The battery is under low battery status please replace the device The device sounds unwanted alarms when residents are cooking taking showers etc 1 Press TEST SILENCE button to pause alarm 2 Clean the smoke around the device 6 General maintenance To keep your Combo Smoke CO alarm in good workin...

Страница 10: ...ration state after several hours However the rate at which the equilibrium is reached depends on many factors e g lung ventilation rate physical activity and alveolar capillary transfer cardiac parameters blood haemoglobin concentration barometric pressure oxygen and carbon dioxide concentration in the inhaled air but the two most important factors in determining the COHb level are the CO concentr...

Страница 11: ...w levels of COHb of between 0 3 and 0 7 present within the body These levels are considered neither beneficial nor harmful 7 4 Tobacco smoking Tobacco smokers are exposed to significant concentrations of CO In cigarette smokers the COHb concentration varies between 5 9 while heavy cigar smokers may exceed 10 WARNING Exposure to high levels of carbon monoxide can be fatal or cause permanent damage ...

Страница 12: ...ours Installation Location ceiling or wall Detection range Max 40 m2 within a room Size about Φ134 40mm Weight 185 10g net NOTE This Combo Smoke CO alarm is designed to detect carbon monoxide gas from any source of combustion It is not designed to detect any other gas 10 Deactivation of the device WARNING Deactivation of the device is permanent Once the device has been deactivated it cannot be rea...

Страница 13: ...ergency 12 Manufacturer and customer service information 12 1 Manufacturer SITERWELL ELECTRONICS CO LIMITED ADDRESS No 666 Qingfeng Road Jiangbei District Ningbo Zhejiang Province China TEL 0086 574 87729581 FAX 0086 574 87729581 E MAIL sales china siter com 12 2 Customer service SITERWELL ELECTRONICS CO LIMITED ADDRESS No 666 Qingfeng Road Jiangbei District Ningbo Zhejiang Province China TEL 0086...

Страница 14: ...ce NOTE The warranty does not cover the batteries supplied 14 Warranty card Last Name First Name Phone Address City Country Zip Code Fault description Date of purchase Signature 14 14 GS883 A Instruction Manual Rev G ...

Отзывы: