background image

Prepare and practice a home escape plan twice a 
year, including drills at night. Know of two ways 
out of every room (door & window) and identify a 
meeting place outside the home where everyone will
gather once they have exited the residence. When 
two people have reached the meeting place, one 
should leave to call the fire department's telephone 
number ( ______________ ) while the second person
stays to account for additional family members. 

Establish a rule that once you're out, you never 
re-enter under any circumstance!

■ Make a floor plan indicating all doors and 
windows and least two escape routes from each 
room. Second story windows may need a rope or 
chain ladder.
■ Have a family meeting and discuss your escape 
plan, showing everyone what to do in case of fire 
and where to meet after they leave the house.
■ Ensure that small children hear the alarm and 
wake when it sounds. They must wake up in order to
execute the escape plan. Practice allows all 
occupants to test your plan before an emergency. 
You may not be able to reach your children. It is 
important they know what to do.
■ Familiarise everyone with the sound of the smoke/
CO alarm and train them to leave your home when 
they hear it.
■ Current studies have shown smoke/CO alarms may
not awaken all sleeping individuals, and that it is the
responsibility of individuals in the household that 
are capable of assisting others to provide assistance 
to those who may not be awakened by the alarm 
sound, or to those who may be incapable of safely 
evacuating the area unassisted.
■ Install and maintain fire extinguishers on every 
level of the home and in the kitchen, basement and 
garage. Know how to use a fire extinguisher prior to
an emergency.

12. Manufacturer and customer    

service information:               

12.1 Manufacturer:

SITERWELL ELECTRONICS CO., LIMITED
ADDRESS: No.666 Qingfeng Road, Jiangbei 
District, Ningbo, Zhejiang Province, China
TEL: 

0086-574-87729581

FAX: 

0086-574-87729581

E-MAIL:

 [email protected]

12.2 Customer service:

SITERWELL ELECTRONICS CO., LIMITED
ADDRESS: No.666 Qingfeng Road, Jiangbei 
District, Ningbo, Zhejiang Province, China
TEL: 

0086-574-87729581

FAX: 

0086-574-87729581

E-MAIL:

 

[email protected]

13. Warranty information

THREE YEARS LIMITED WARRANTY

Dear customer,

O u r   p r o d u c t s   a r e   s u b j e c t   t o   s t r i c t   q u a l i t y

c

o

n

t

r

o

l

s

.

 

H

o

w

e

v

e

r

,

 

i

f

 

t

h

i

s

 

d

e

v

i

c

e

 

s

h

o

u

l

d

u n e x p e c t e d l y   n o t   f u n c t i o n   p e r f e c t l y,   p l e a s e   c o n t a c t
t h e   c u s t o m e r   s e r v i c e s   a d d r e s s   g i v e n   o n   w a r r a n t y
service information. This is the only way for you to
b e   a b l e   t o   r e t u r n   y o u r   d e v i c e   o r   h a v e   i t   p i c k e d   u p
free.

The warranty period is 36 months and begins on

the day of purchase.

Please always keep your till receipt as proof of 

purchase. Warranty claims can only be made for 
possible defects caused by material and production 
faults.

During the warranty period, defective devices 

can be sent to the service address given overleaf for 
you (postage paid). You will then receive a new or 
repaired device back free. After the warranty period 
has expired you still have the possibility of sending 
the defective device for repair to the address given 
overleaf. Repairs carried out after the warranty 
period must be paid for.

 

In the event of misuse or improper treatment, 

use of force or intervention not carried out by our 
authorized service branches, the warranty is no 
longer valid. This warranty does not restrict your 
legal rights.

NOTE: In the event of a warranty claim, please 
return the till receipt and completed warranty 
card with fault description together with the 

             

13

 / 

14                      

GS883-A Instruction Manual Rev. G

Содержание GS883-A

Страница 1: ...e long beeps repeating every 1 5 seconds The ALARM indicator red will flash the same pattern The smoke alarm takes precedence when both smoke and carbon monoxide are present 1 1 What to do in case of fire 1 Do not panic stay calm 2 Leave the building as quickly as possible Touch doors to feel if they are hot do not open but use an alternate exit that is not hot Crawl along the floor and do not sto...

Страница 2: ...r the national Gas Emergency Service Provider if appropriate so that the source of carbon monoxide emissions can be identified and corrected Unless the reason for the alarm is obviously spurious do not use the fuel burning appliances again until they have been checked and cleared for use by a competent person according to national regulations If problems are identified during this inspection have ...

Страница 3: ...oke CO alarm will not promptly detect a fire or CO danger except in the area or room in which it is installed 6 This Combo Smoke CO alarm may not alert every household member every time The alarm horn is loud in order to alert individuals to a potential danger However there may be some circumstances where a household member may not hear the alarm i e outdoor or indoor noise sound sleepers drug or ...

Страница 4: ...d i e portable heaters or humidifiers 5 L o c a t e 1 0 f e e t a w a y f r o m a l appliances 6 Placing at eye level allows for optimum monitoring of the red and green indicator lights 7 Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the centre of the room places it closest to all points in the room Ceiling mounting is pre...

Страница 5: ...ombustion are present when you start your automobile 8 In an enclosed space for example in a cupboard or behind a curtain 9 Where it can be obstructed for example by furniture 10 Less than 4 inch 10cm from the peak of an A frame type ceiling 11 Near fluorescent lights Electronic noise may cause nuisance alarms 12 Place out of the reach of children Under no circumstances should children be allowed ...

Страница 6: ...m status of the smoke alarm or CO alarm 4 TEST SILENCE button The TEST SILENCE button is used to test the device and to silence the unit during a smoke alarm Press and hold to enable TEST function Or press to enable SILENCE function 5 Sounder The sounder is used to send out smoke alarm CO alarm warning and abnormal warning information 6 Power on switch The power on switch is used to power on the d...

Страница 7: ...sing the TEST SILENCE button it will come into a low battery voltage warning silence status for about 9 hours and FAULT indicator yellow continue to flash NOTE The silence feature of low battery voltage warning is temporary action to cancel warning sound effect you need to replace the device as possible as soon 6 Smoke alarm When the device detects a dangerous level of smoke the device will emit a...

Страница 8: ...If the CO alarm sounds and it is not being tested it means the unit is sensing a dangerous level of CO THE SOUND OF THE ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION 9 Human alarm sounds If the device enters into the status of smoke alarm or C O a l a r m t h e d e v i c e w i l l s t a r t i n a l o w e volume 85dB for around 10 seconds then emits a normal alarm volume 85dB This avoids start...

Страница 9: ...vice chirps twice with FAULT indicator yellow flashing twice every 40 seconds LOW BATTERY VOLTAGE SIGNAL The battery is under low battery status please replace the device The device sounds unwanted alarms when residents are cooking taking showers etc 1 Press TEST SILENCE button to pause alarm 2 Clean the smoke around the device 6 General maintenance To keep your Combo Smoke CO alarm in good workin...

Страница 10: ...ration state after several hours However the rate at which the equilibrium is reached depends on many factors e g lung ventilation rate physical activity and alveolar capillary transfer cardiac parameters blood haemoglobin concentration barometric pressure oxygen and carbon dioxide concentration in the inhaled air but the two most important factors in determining the COHb level are the CO concentr...

Страница 11: ...w levels of COHb of between 0 3 and 0 7 present within the body These levels are considered neither beneficial nor harmful 7 4 Tobacco smoking Tobacco smokers are exposed to significant concentrations of CO In cigarette smokers the COHb concentration varies between 5 9 while heavy cigar smokers may exceed 10 WARNING Exposure to high levels of carbon monoxide can be fatal or cause permanent damage ...

Страница 12: ...ours Installation Location ceiling or wall Detection range Max 40 m2 within a room Size about Φ134 40mm Weight 185 10g net NOTE This Combo Smoke CO alarm is designed to detect carbon monoxide gas from any source of combustion It is not designed to detect any other gas 10 Deactivation of the device WARNING Deactivation of the device is permanent Once the device has been deactivated it cannot be rea...

Страница 13: ...ergency 12 Manufacturer and customer service information 12 1 Manufacturer SITERWELL ELECTRONICS CO LIMITED ADDRESS No 666 Qingfeng Road Jiangbei District Ningbo Zhejiang Province China TEL 0086 574 87729581 FAX 0086 574 87729581 E MAIL sales china siter com 12 2 Customer service SITERWELL ELECTRONICS CO LIMITED ADDRESS No 666 Qingfeng Road Jiangbei District Ningbo Zhejiang Province China TEL 0086...

Страница 14: ...ce NOTE The warranty does not cover the batteries supplied 14 Warranty card Last Name First Name Phone Address City Country Zip Code Fault description Date of purchase Signature 14 14 GS883 A Instruction Manual Rev G ...

Отзывы: