(green /yellow/red) will light up briefly and the 
device confirms start-up with a beep.
After power on, 40 seconds before the POWER 
indicator (green) flash every 2 seconds. This is pre-
heated state, 40 seconds later the POWER indicator 
(green) flashing every 40 seconds indicates the 
device is functioning properly.

2. Normal operation

The POWER indicator (green) flashing every 40 

seconds.

3. Fault warning

If the device chirps twice every 40 seconds, with 
FAULT indicator (yellow) will be flashing. It 
indicates the device is in a malfunctioning 
condition. That means your device has no detecting 
feature and no response to smoke and CO.

     

CAUTION! -

When Fault warning occurs, 

replace the device immediately. Please contact us
to more service. 

     

CAUTION! -

When Fault warning occurs, 

please refer to "10. Deactivation of alarm" to 
dispose the device.

4. Low battery voltage warning

If the device chirps once every 40 seconds, with 
FAULT indicator (yellow) will be flashing.

 

It 

indicates the battery is low. 

NOTE: When the low battery voltage warning 
occurs the device is capable of producing a smoke
alarm signal or CO alarm signal for at least 4 min
or 30 days of low battery voltage warning signal 
operation.

NOTE: You need to replace the device as possible 
as soon when the device enters this status. 

NOTE: The device will not protect against the risk
of smoke and carbon monoxide poisoning when 
the battery has drained. 

NOTE: Refer to “10. Deactivation of the device” 
to dispose the device.

5. Low battery voltage warning silence

When the device is under the low battery warning, 
pressing the TEST/SILENCE button, it will come 
into a low battery voltage warning silence status for
about 9 hours, and FAULT indicator (yellow) 
continue to flash.

NOTE: The silence feature of low battery voltage 
warning is temporary action to cancel  warning 
sound effect, you need to replace the device as 
possible as soon. 

6. Smoke alarm

When the device detects a dangerous level of 
smoke, the device will emit a smoke alarm pattern. 
The smoke alarm signal pattern is 3 long beeps 
followed by 1.5 seconds of silence. This cycle 
repeats as long as a dangerous smoke condition 
exists. The ALARM indicator(red) will flash the 
same pattern. 
This signal will repeated until dissipation of smoke 
or the alarm signal is manually silenced. 

    CAUTION!

 -Refer to “1. What to do if the 

smoke alarm sounds” when you hear the sounds 
of the smoke alarm warning.

     

DANGER! -

If the smoke alarm sounds, and

it is not being tested, it means the unit is sensing 
smoke, THE SOUND OF THE ALARM 
REQUIRES YOUR IMMEDIATE ATTENTION 
AND ACTION.  

7. Smoke alarm silence

During the device under smoke alarm mode, push the
TEST/SILENCE button, it will pause the device alarm
sound for about 10 minutes. The ALARM indicator 
(red) will keep flashing in smoke alarm mode, it 
indicates the device is running into the smoke alarm
silence mode. This Combo Smoke/CO alarm is 
designed to minimise nuisance alarms. Combustion 
particles from cooking may set off the alarm if the 
alarm is located close to the cooking area. Large 
quantities of combustible particles are generated 
from spills or when grilling/frying. Using the fan on
a range hood that vents to outside (non-recirculating
type) will also help remove these combustible 
particles from the kitchen. The smoke alarm silence 

             

7

 / 

14                      

GS883-A Instruction Manual Rev. G

Содержание GS883-A

Страница 1: ...e long beeps repeating every 1 5 seconds The ALARM indicator red will flash the same pattern The smoke alarm takes precedence when both smoke and carbon monoxide are present 1 1 What to do in case of fire 1 Do not panic stay calm 2 Leave the building as quickly as possible Touch doors to feel if they are hot do not open but use an alternate exit that is not hot Crawl along the floor and do not sto...

Страница 2: ...r the national Gas Emergency Service Provider if appropriate so that the source of carbon monoxide emissions can be identified and corrected Unless the reason for the alarm is obviously spurious do not use the fuel burning appliances again until they have been checked and cleared for use by a competent person according to national regulations If problems are identified during this inspection have ...

Страница 3: ...oke CO alarm will not promptly detect a fire or CO danger except in the area or room in which it is installed 6 This Combo Smoke CO alarm may not alert every household member every time The alarm horn is loud in order to alert individuals to a potential danger However there may be some circumstances where a household member may not hear the alarm i e outdoor or indoor noise sound sleepers drug or ...

Страница 4: ...d i e portable heaters or humidifiers 5 L o c a t e 1 0 f e e t a w a y f r o m a l appliances 6 Placing at eye level allows for optimum monitoring of the red and green indicator lights 7 Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the centre of the room places it closest to all points in the room Ceiling mounting is pre...

Страница 5: ...ombustion are present when you start your automobile 8 In an enclosed space for example in a cupboard or behind a curtain 9 Where it can be obstructed for example by furniture 10 Less than 4 inch 10cm from the peak of an A frame type ceiling 11 Near fluorescent lights Electronic noise may cause nuisance alarms 12 Place out of the reach of children Under no circumstances should children be allowed ...

Страница 6: ...m status of the smoke alarm or CO alarm 4 TEST SILENCE button The TEST SILENCE button is used to test the device and to silence the unit during a smoke alarm Press and hold to enable TEST function Or press to enable SILENCE function 5 Sounder The sounder is used to send out smoke alarm CO alarm warning and abnormal warning information 6 Power on switch The power on switch is used to power on the d...

Страница 7: ...sing the TEST SILENCE button it will come into a low battery voltage warning silence status for about 9 hours and FAULT indicator yellow continue to flash NOTE The silence feature of low battery voltage warning is temporary action to cancel warning sound effect you need to replace the device as possible as soon 6 Smoke alarm When the device detects a dangerous level of smoke the device will emit a...

Страница 8: ...If the CO alarm sounds and it is not being tested it means the unit is sensing a dangerous level of CO THE SOUND OF THE ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION 9 Human alarm sounds If the device enters into the status of smoke alarm or C O a l a r m t h e d e v i c e w i l l s t a r t i n a l o w e volume 85dB for around 10 seconds then emits a normal alarm volume 85dB This avoids start...

Страница 9: ...vice chirps twice with FAULT indicator yellow flashing twice every 40 seconds LOW BATTERY VOLTAGE SIGNAL The battery is under low battery status please replace the device The device sounds unwanted alarms when residents are cooking taking showers etc 1 Press TEST SILENCE button to pause alarm 2 Clean the smoke around the device 6 General maintenance To keep your Combo Smoke CO alarm in good workin...

Страница 10: ...ration state after several hours However the rate at which the equilibrium is reached depends on many factors e g lung ventilation rate physical activity and alveolar capillary transfer cardiac parameters blood haemoglobin concentration barometric pressure oxygen and carbon dioxide concentration in the inhaled air but the two most important factors in determining the COHb level are the CO concentr...

Страница 11: ...w levels of COHb of between 0 3 and 0 7 present within the body These levels are considered neither beneficial nor harmful 7 4 Tobacco smoking Tobacco smokers are exposed to significant concentrations of CO In cigarette smokers the COHb concentration varies between 5 9 while heavy cigar smokers may exceed 10 WARNING Exposure to high levels of carbon monoxide can be fatal or cause permanent damage ...

Страница 12: ...ours Installation Location ceiling or wall Detection range Max 40 m2 within a room Size about Φ134 40mm Weight 185 10g net NOTE This Combo Smoke CO alarm is designed to detect carbon monoxide gas from any source of combustion It is not designed to detect any other gas 10 Deactivation of the device WARNING Deactivation of the device is permanent Once the device has been deactivated it cannot be rea...

Страница 13: ...ergency 12 Manufacturer and customer service information 12 1 Manufacturer SITERWELL ELECTRONICS CO LIMITED ADDRESS No 666 Qingfeng Road Jiangbei District Ningbo Zhejiang Province China TEL 0086 574 87729581 FAX 0086 574 87729581 E MAIL sales china siter com 12 2 Customer service SITERWELL ELECTRONICS CO LIMITED ADDRESS No 666 Qingfeng Road Jiangbei District Ningbo Zhejiang Province China TEL 0086...

Страница 14: ...ce NOTE The warranty does not cover the batteries supplied 14 Warranty card Last Name First Name Phone Address City Country Zip Code Fault description Date of purchase Signature 14 14 GS883 A Instruction Manual Rev G ...

Отзывы: