Smart Thermostat (Transmitter Operation)
The Smart Thermostat function adjusts the flame height in accordance to the difference
between the set point temperature and the actual room temperatures. As the room
temperature gets closer to the set point the Smart Function will modulate the flame down.
To activate this function, press the Thermostat Key (Fig. 1) until the word "SMART" appears to
the right of the temperature bulb graphic (Fig. 11).
To adjust the set temperature, press the Up or Down Arrow Keys until the desidered set
temperature is displayed on the LCD screen of the transmitter (Fig. 12).
Note. When Smart Thermostat is activated, manual flame height adjustment is disabled.
Fan Speed Control
If the appliance is equipped with a hot air circulating fan, the speed of the fan can be
controlled by the Proflame system. The fan speed can be adjusted through six (6) speeds. To
activate this function use the Mode Key (fig.1) to index to the fan control icon (Fig. 13). Use the
Up/Down Arrow Keys (Fig.1) to turn on, off or adjust the fan speed (fig. 14). A single “beep”
will confirm reception of the command.
Continous Pilot/Intermittent Pilot (CPI/IPI) selection
With the system in "OFF" position press the Mode Key (fig. 1) to index to the CPI mode icon
(fig. 17 & 18).
Pressing the Up Arrow Key will activate the Continous Pilot Ignition mode (CPI). Pressing the
Down Arrow Key will return to IPI. A single “beep” will confirm the reception of the command.
NOTE: this function is available only with Proflame IFC.
NOTE: If the system is equipped with a CPI/IPI toggle switch:
• Set the CPI/IPI switch to CPI position(switch closed) to enable remote CPI/IPI
operation.
• Set the CPI/IPI switch to IPI position (switch open) to disable remote CPI/IPI
operation. The system will now work in IPI mode only regardless of the selection on
the remote control hand set.
Remote auxiliary relay control
The auxiliary function controls the AUX relay outlet. To activate this function use the Mode Key
(fig. 1) to index to the AUX icon (fig. 15 & 16).
Pressing the Up Arrow Key will activate the outlet. Pressing the Down Arrow Key will turn the
outlet off. A single “beep” will confirm the reception of the command.
Fig. 15
Fig. 16
Fig. 17
Fig. 18
9955126_A00_Proflame_Wall_Mount_7 7