background image

4

Initializing the System for the first time

1. Power the receiver (install receiver batteries if necessary).
2. Turn the receiver control on, or verify the receiver control 

is on.

3.  Activate  the  programming  mode  on  the  receiver 

according to the receiver instructions (NOTE: The receiver 
may  be  independent  or  integrated  to  the  IFC  (Ignitions 
and  Flame  Control)  hearth  appliance  control  module.  
The receiver instructions may be included with the IFC if 
an integrated system.)

4. The receiver will “beep” three (3) times to indicate that it 

is ready to synchronize with a transmitter.

5. Install three AAA batteries in the transmitter, located as 

shown in Fig. 3.

6.  The  receiver  will  “beep”  four  times  to  indicate  the 

transmitter’s  command  is  accepted  and  sets  to  the 
particular code of that transmitter.

7. The system is now initialized.

opeRATING pRoceduRe

Turn on the Appliance

With  the  system  OFF,  press  the  ON/OFF  Key  on  the 
transmitter. The transmitter display will show some other 
active icons on the screen. At the same time the receiver 
wil  activate  the  appliance.  A  single  “beep”  from  the 
receiver will confirm reception of the command.

Turn off the Appliance

With  the  system  ON,  press  the  ON/OFF  Key  on  the 
transmitter.  The  transmitter  LCD  display  will  only  show 
the  room  temperature  (Fig.  6).  At  the  same  time  the 
receiver will turn off the appliance. A single “beep” from 
the receiver confirms reception of the command.

Fig. 6: Remote Control display.

Temperature indication Display 
With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same 
time. Look at the LCD screen on the transmitter to verify that a C or F is visible to the right of 
the Room Temperature display. (Fig. 4 and fig. 5)

Fig. 3: Battery compartment.

Fig. 4: Remote Control display in Farenheit.       Fig. 5: Remote Control display in Celsius.

Remote‑Flame Control
The Proflame has six (6) flame levels. With the system on, and the flame level at the maximum 
in the appliance, pressing the Down Arrow Key once will reduce the flame height by one step 
until the flame is turned off.
The Up Arrow Key will increase the flame height each time it is pressed. If the Up Arrow Key is pressed 
while the system is on but the flame is off, the flame will come on in the high position setting. ( Fig. 7 & 8 ) 
A single “beep” will confirm reception of the command.

Fig. 9

Fig. 10

SET TEMPERATURE

ROOM TEMPERATURE

Room Thermostat ( Transmitter Operation)

The Remote Control can operate as a room thermostat. The thermostat can be set to a desired 
temperature to control the comfort level in a room.
To activate this function, press the Thermostat Key (Fig. 1). The LCD display on the transmitter 
will  change  to  show  that  the  room  thermostat  is  “ON”  and  the  set  temperature  is  now 
displayed (Fig. 9). To adjust the set temperature, press the Up or Down Arrow Keys until the 
desired set  temperature is displayed on the LCD screen of the transmitter.

Fig. 7:  

  Flame Off 

 

 

  

Flame Level 1 

Fig. 8:  

  Flame level 5   

Flame Level Maximum

9955126_A00_Proflame_Wall_Mount_4   4

24/02/2014   15.42.15

Содержание Proflame

Страница 1: ...ADVANCED REMOTE CONTROL SYSTEM PROFLAME WALL MOUNT TRANSMITTER 9 955 126 A00 Subject to change without notice w w w s i t g r o u p i t 9955126_A00_Proflame_Wall_Mount_1 1 24 02 2014 15 41 51 ...

Страница 2: ...lay 8 Comfort Fan speed modulation 6 levels The Proflame transmitter uses a streamlined design with a simple button layout and informative LCD display Fig 1 A Mode Key is provided to index between the features and a Thermostat Key is used to turn on off or index through Thermostat functions Fig 1 2 Additionally a Key Lock feature is provided Fig 23 Fig 1 Proflame transmitter Back lit LCD display U...

Страница 3: ...d with low battery level Remote Control Supply voltage 4 5 V three AAA LR03 1 5 V batteries Ambient temperature ratings 0 50 C 32 122 F Typical operative distance in free air 12 m 39 ft Radio frequency 315 MHz FCC version 433 92 MHz CE version TECHNICAL DATA The Proflame remote control is supplied with an adapter for wall mounting Installthecontroller1 5m 5ft abovefloorlevel wellawayfromheatsource...

Страница 4: ...e Appliance With the system OFF press the ON OFF Key on the transmitter The transmitter display will show some other active icons on the screen At the same time the receiver wil activate the appliance A single beep from the receiver will confirm reception of the command Turn off the Appliance With the system ON press the ON OFF Key on the transmitter The transmitter LCD display will only show the ...

Страница 5: ...mmand Fig 9 Fig 10 SET TEMPERATURE ROOM TEMPERATURE Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat The thermostat can be set to a desired temperature to control the comfort level in a room To activate this function press the Thermostat Key Fig 1 The Lcd display on the transmitter will change to show that the room thermostat is ON and the set temperature i...

Страница 6: ...esidered set temperature is displayed on the LCD screen of the transmitter Fig 12 Note When Smart Thermostat is activated manual flame height adjustment is disabled Fan Speed Control If the appliance is equipped with a hot air circulating fan the speed of the fan can be controlled by the Proflame system The fan speed can be adjusted through six 6 speeds To activate this function use the Mode Key f...

Страница 7: ...CPI IPI switch to CPI position switch closed to enable remote CPI IPI operation Set the CPI IPI switch to IPI position switch open to disable remote CPI IPI operation The system will now work in IPI mode only regardless of the selection on the remote control hand set Remote auxiliary relay control The auxiliary function controls the AUX relay outlet To activate this function use the Mode Key fig 1...

Страница 8: ...ion of the command Note This function is available only with the Proflame IFC Fig 19 Fig 20 Split Flow control The secondary burner is controlled by the split Flow To activate this function use the Mode Key fig 1 to index to the SPLIT FLOW mode icon fig 21 22 Pressing the Up Arrow Key will activate the secondary burner Pressing the Down Arrow Key will turn the secondary burner off A single beep wi...

Страница 9: ...remote control batteries depends on various factors quality of the batteries used the number of ignitions of the appliance the number of changes to the room thermostat set point etc When the transmitter batteries are low a Battery icon will appear on the LCD display of the transmitter Fig 24 before all battery power is lost When the batteries are replaced this icon will disappear LOW BATTERY pOwer...

Страница 10: ...lowing requirements FCC Federal Communications Commission Part 15 Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Changes or modification not expressly approved by the party responsible for compliance could void the user s authority...

Страница 11: ...11 Fig 24 PROFLAME transmitter dimensional drawing Dimensional drawings Dimensions in millimeters 152 63 63 26 26 Ø3 Ø3 9955126_A00_Proflame_Wall_Mount_11 11 24 02 2014 15 42 25 ...

Страница 12: ...T La Precisa S p A Viale dell Industria 31 33 35129 PADOVA ITALY Tel 39 049 829 31 11 Fax 39 049 807 00 93 www sitgroup it e mail mkt sitgroup it 9955126_A00_Proflame_Wall_Mount_12 12 24 02 2014 15 42 26 ...

Отзывы: