background image

10

WARNING
fire hazard. can cause severe injury or death

The  transmitter  causes  ignition  of  the  appliance.  The  appliance  can  turn  on 
suddenly. Keep away from the appliance burner when operating the remote system.  

fcc coNfoRmITy (for 315mhz version only)

  The “proflame Wall mount transmitter” complies with the following requirements: 
   

- fcc (federal communications commission) part 15 

  operation is subject to the following two conditions: 
   

(1) This device may not cause harmful interference, and 

   

(2) This device must accept any interference received, including interference    

   

that may cause undesired operation. 

  changes or modification not expressly approved by the party responsible for  

 

  compliance could void the user’s authority to operate the equipment. 

  fcc Id: T99058404300

dImeNsIoNAl dRAWINGs

152

63

63

26

26

Ø3

Ø3

9955126_A00_Proflame_Wall_Mount_10   10

24/02/2014   15.42.25

Содержание Proflame

Страница 1: ...ADVANCED REMOTE CONTROL SYSTEM PROFLAME WALL MOUNT TRANSMITTER 9 955 126 A00 Subject to change without notice w w w s i t g r o u p i t 9955126_A00_Proflame_Wall_Mount_1 1 24 02 2014 15 41 51 ...

Страница 2: ...lay 8 Comfort Fan speed modulation 6 levels The Proflame transmitter uses a streamlined design with a simple button layout and informative LCD display Fig 1 A Mode Key is provided to index between the features and a Thermostat Key is used to turn on off or index through Thermostat functions Fig 1 2 Additionally a Key Lock feature is provided Fig 23 Fig 1 Proflame transmitter Back lit LCD display U...

Страница 3: ...d with low battery level Remote Control Supply voltage 4 5 V three AAA LR03 1 5 V batteries Ambient temperature ratings 0 50 C 32 122 F Typical operative distance in free air 12 m 39 ft Radio frequency 315 MHz FCC version 433 92 MHz CE version TECHNICAL DATA The Proflame remote control is supplied with an adapter for wall mounting Installthecontroller1 5m 5ft abovefloorlevel wellawayfromheatsource...

Страница 4: ...e Appliance With the system OFF press the ON OFF Key on the transmitter The transmitter display will show some other active icons on the screen At the same time the receiver wil activate the appliance A single beep from the receiver will confirm reception of the command Turn off the Appliance With the system ON press the ON OFF Key on the transmitter The transmitter LCD display will only show the ...

Страница 5: ...mmand Fig 9 Fig 10 SET TEMPERATURE ROOM TEMPERATURE Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat The thermostat can be set to a desired temperature to control the comfort level in a room To activate this function press the Thermostat Key Fig 1 The Lcd display on the transmitter will change to show that the room thermostat is ON and the set temperature i...

Страница 6: ...esidered set temperature is displayed on the LCD screen of the transmitter Fig 12 Note When Smart Thermostat is activated manual flame height adjustment is disabled Fan Speed Control If the appliance is equipped with a hot air circulating fan the speed of the fan can be controlled by the Proflame system The fan speed can be adjusted through six 6 speeds To activate this function use the Mode Key f...

Страница 7: ...CPI IPI switch to CPI position switch closed to enable remote CPI IPI operation Set the CPI IPI switch to IPI position switch open to disable remote CPI IPI operation The system will now work in IPI mode only regardless of the selection on the remote control hand set Remote auxiliary relay control The auxiliary function controls the AUX relay outlet To activate this function use the Mode Key fig 1...

Страница 8: ...ion of the command Note This function is available only with the Proflame IFC Fig 19 Fig 20 Split Flow control The secondary burner is controlled by the split Flow To activate this function use the Mode Key fig 1 to index to the SPLIT FLOW mode icon fig 21 22 Pressing the Up Arrow Key will activate the secondary burner Pressing the Down Arrow Key will turn the secondary burner off A single beep wi...

Страница 9: ...remote control batteries depends on various factors quality of the batteries used the number of ignitions of the appliance the number of changes to the room thermostat set point etc When the transmitter batteries are low a Battery icon will appear on the LCD display of the transmitter Fig 24 before all battery power is lost When the batteries are replaced this icon will disappear LOW BATTERY pOwer...

Страница 10: ...lowing requirements FCC Federal Communications Commission Part 15 Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Changes or modification not expressly approved by the party responsible for compliance could void the user s authority...

Страница 11: ...11 Fig 24 PROFLAME transmitter dimensional drawing Dimensional drawings Dimensions in millimeters 152 63 63 26 26 Ø3 Ø3 9955126_A00_Proflame_Wall_Mount_11 11 24 02 2014 15 42 25 ...

Страница 12: ...T La Precisa S p A Viale dell Industria 31 33 35129 PADOVA ITALY Tel 39 049 829 31 11 Fax 39 049 807 00 93 www sitgroup it e mail mkt sitgroup it 9955126_A00_Proflame_Wall_Mount_12 12 24 02 2014 15 42 26 ...

Отзывы: