22 

 

6.6. COMMUNICATION PARAMETERS 

 

For this section, check the manual “AGRÓNIC 2500 Communications Supplement”. 

 

 

6.7. VARIOUS PARAMETERS 

 

The LCD screen can shut off automatically in order to reduce power 

consumption;  the  screen  will  shut  off  without  showing  information  after 

five minutes have elapsed since the last time the keyboard was pressed. It 
activates automatically by pressing any key. 

The  screen  can  be  illuminated  for  easy  reading  in  low-light  situa-

tions; just respond yes to the question to have the screen normally illumi-

nated. When the screen automatically shuts  off, the light will also switch 

off. It is possible to manually turn the illumination on or off by pressing the 

“0” key when we are in the Consultation menu on in any of the Function 

screen. 

In contrast  we can adjust the contrast the text makes on the back-

ground; the scale runs from 0, the lightest, to 10, the darkest. 

 

The keyboard functions by detecting fingertips pressed on the key outlines. As there are no mechanical parts, 

the sensitivity may be adjusted, which determines the contact area that will interpret a pressed key; a value of 1 is 

for less sensitive detection and 5 for the most sensitive. 

At the same time when a key is pressed, the equipment emits a “beep”, whose sound level we may adjust; 

the lowest being a “1” and the loudest a “5”; use “0” for no sound. 

 

After entering a number in the PIN code, the theft protection is activated. If Agrónic is above 10' without pow-

er  supply,  it  will  require  the  PIN  code  to  be  fed  again.  If  the  wrong  activation  code  is  entered  three  times,  the 

Agrónic gets blocked, asking for the deactivation code (PUK). You will need to contact the PROGRÉS in order to 

obtain the deactivation code. If you do not want to use this protection, leave the PIN code to 0. 

If you want to change the  PIN code, you must first enter the current PIN, otherwise you will  not be able to 

change it. 

 

 

6.8. INSTALLER PARAMETERS 

 

This configuration is done by the installer when activating the Agrónic 

2500 and can only be modified by the installer for extensions or modifica-

tions made to the equipment or facility. 

1. Erasure, allows the memory be entirely erased, and also records, 

programs and sectors to be erased. 

2. Events, in the standard version it is not possible to make modifica-

tions. 

3.  Access  codes,  enables  the  limited  access  to  the  Parameters, 

Functions  or  Total  Erasure  sections,  entering  here  the  4-digit  code  re-

questing access. Leave the value at 0 if this is not necessary. 

4. Option activation, used to activate or deactivate options once they

 

have

 

been

 

installed

 

on

 

the equipment.

 

In

 

order

 

to

 

activate

 

them,

 

enter

 

the

 

code

 

provided

 

by

 

PROGRÉS,

 

and to de-

activate them enter an erroneous code. The activated option will display a “*” to the right of the text for the option. 

5. Various

 

Limit on sectors, from 1 to 8. With this simultaneous irrigation will be limited to the number of sectors 

entered here. In practice, if more sectors are entered, these will be postponed until those being irrigat-

ed have finished. It only affects the sectors connected to the outputs of the base. 

 

Limit on sectors in program, from 1 to 4. Each irrigation program can activate up to 4 sectors at the 

same  time  in  the  same  irrigation  conditions.  Enter  here  the  appropriate  value  according  to  the  pro-

gramming requirements. 

 

Alternating sequences, for sequential irrigations made in one group of sectors. When one sector has 

finished, the next automatically begins, and if desired, the order can be alternated to avoid having sec-

tors always being irrigated at the same time, to which the question must be answered affirmatively. 

 

Sequential with 99:00? If this parameter is set to YES it means that a program is sequential from an-
other program and this is done by indicating 99 at the starting time field. Example: in order to indicate 

that the current program is sequential from program 2, it must be set 99:02. 

 

Ask for the time in irrigations per volume, used from programs carrying out irrigation by volume and it 

is necessary to have an irrigation time limit for safety reasons. 

  VARIOUS PARAMETERS 

 

  Screen: 

 

  Automatic shut off: yes 

 

  Illumination: yes 

 

  Contrast: 5 

 

   

 

  Keyboard: 

 

  Sensitivity: 3 

 

  Sound level: 2 

 

   

 

  PIN security 

 

  PIN code: 0000 

 

   

 

 

INSTALLER PARAM. 

 

  1. Erasure 

 

  2. Events 

 

  3. Access codes 

 

  4. Act. of options 

 

  5. Various 

 

  6. Communications 

 

  7. Language 

 

  8. Updating software 

 

  9. Backup param. 

 

Содержание AGRONIC 2500

Страница 1: ...S 22 6 9 DIESEL OPTION PARAMETERS 23 Sections for the user 7 PROGRAMS 24 7 1 SEQUENTIAL PROGRAMS 25 7 1 1 Alternating sequential programs 26 7 2 FERTILIZATION 27 8 MANUAL 28 9 READINGS 30 9 1 READINGS TOTALS 30 9 2 READINGS ANOMALIES 30 10 CONSULTATION 32 10 1 CONSULTATION GENERAL 32 10 2 CONSULTATION PROGRAMS 33 10 3 CONSULTATION SECTORS 34 10 4 CONSULTATION FERTILIZERS 35 10 5 CONSULTATION FILTE...

Страница 2: ...to 30 irrigation sectors can be controlled which are governed by 50 separate programs with their corresponding extensions with the possibility of linking programs together to execute irrigation sequences Each program can activate 1 to 4 irrigation sectors simultaneously It can limit the simultaneous ac tivation of sectors of the base from 1 to 8 among several programs Each program can start runnin...

Страница 3: ...Temporizations are set to input and output for each sector Optionally a diesel engine or generator unit can also be controlled Outputs for start up stop con tact and preheating functions are available Start stop control of the electrical pump as well as malfunc tions detection is also performed FILTER CLEANING Configurable for 0 to 9 filters with selectable cleaning time Pause between filters is p...

Страница 4: ...y management of up to 4 pivots with start and stop control positioning auto reverse speed control sectorisation and alarms DISPLAY Full display using a LCD screen 128x64 pixel graphics LED automatic backlighting Watertight keypad features 15 keys with sound indicators when pressed Available in Spanish English French Italian Portuguese and Catalan Entire program information is shown onscreen simult...

Страница 5: ...or Server Wi Fi LAN connection at a short distance and Internet for long distance Radio distances from 1 to 20 km depending on the orography Shares the radio channel with other units in order to be grouped into property dispersion or communities From the AGRÓNIC PC punctual information can be obtained from the controller history incidents irrigation status etc with the capability to modify paramet...

Страница 6: ...n incident occurs Uniform fertilization The uniform application in parallel and by volume is added in order to distrib ute fertilizer more homogenously within the irrigation units New format in the irrigation and fertilization programming in cubic meters per hectare m3 ha and liters per hectare L ha respectively The equipment carries out the calculations for the units ap plied at the start of ever...

Страница 7: ...unit housed in wall hung box with see through window Version with unit housed in box to build in inset in a case or closet Diesel option for automatic start up of pump motors or generators Double voltage option for generators Options with outputs for 2 or 3 wire latch solenoids Due to the very low power consumption of the equipment and electrovalves they operate these versions are highly recommend...

Страница 8: ... of the week Number 5 Thursday for questions related to the days of the week Number 6 Friday for questions related to the days of the week for signs and choice related questions Number 7 Saturday for questions related to the days of the week Number 8 Daily for questions related to the days of the week Number 9 YES when confirming yes no questions for signs and choice related questions Enter key to...

Страница 9: ...y 85 Height 2000 m From 1 0 to 1 6 From 1 1 to 1 5 Pollution Grade 2 Memory and Clock backup Memory No maintenance 10 years for parameters and programs in FRAM memory and FLASH memory records Clock 48 hours without power DECLARATION OF CONFORMITY It follows the 89 336 CEE guidelines for the Electromagnetic Compatibility and the 73 23 CEE guidelines of Low tension for the fulfillment of the product...

Страница 10: ...n opaque cover for the connection housing The 27 output model uses a connector attached to the left side of the box To maintain the isolation of the unit it is essential to keep the panels closed as well as to install cable glands at the cable outlets which are provided with the equip ment For the wall mounting of the unit there are two holed pieces in the upper corners In the built in model a hol...

Страница 11: ...in a connector on the left side The connect ors and antennas from the rest of the options are located on the right side It is recommended to connect the wires to the terminal using the terminal connectors that come with the equipment The terminals accept cables of up to 2 5 mm2 in diameter 5 3 CONNECTIONS The installation must be performed according to the current regulations applying to electrica...

Страница 12: ...ound 5 3 3 Connecting the digital sensors Both the digital sensor inputs and the relay outputs are powered externally to 12 or 24 volts This point to the internal wiring has optical and mechanical safety isolation The device contacts connected to the digital sensor inputs normally have to be open and free of any voltage There are six inputs listed from D1 to D6 plus a common marked CD Each sensor ...

Страница 13: ...13 Example of the connections for a 230 V power supply Example of the connections for a 12 V power supply ...

Страница 14: ...nnecting and disconnecting the contact so the key has to be left in the inactive posi tion At the start up output a supplementary relay is intercalated with a capacity for 30 to 30 amperes connecting the output to the wire from the 50 terminal on the key If the motor is stopped by an electromagnet this is connected to the supplementary relay from the stop out put If the motor is stopped when the f...

Страница 15: ... are available once the generator has been started up The digital inputs have a common CD the negative battery pole the four outputs than using 12 volts have a common the negative battery pole and the other outputs have a 24 V common on the connectors marked as CR 12 Vdc outputs Agrónic 2500 9 outputs Start up 9 Stop 8 Contact 7 Preheating 6 Agrónic 2500 18 outputs Start up 18 Stop 17 Contact 16 P...

Страница 16: ...o the installation to connect the start and stop commons This is unnecessary in 2 wire models 2 WIRE LATCH CONNECTIONS One of the two wires is con nected to the CR output com mon and the other to the corre sponding output between R1 and R27 If the electrovalve activates hydraulically in the opposite di rection than the order given by the equipment this order will be inverted going to Parameters In...

Страница 17: ...uts and common for the power supply output 0 V Example Sensor with independent power supply Connect the common from the sensor to terminal 4 and the sensor signal to terminal 1 or 2 Sensor powered by the Agrónic Connect the common from the sensor to terminal 4 the sensor signal to terminal 1 or 2 and the power supply positive to terminal 3 Sensor with only positive and return Connect the positive ...

Страница 18: ...tion by series and is activated only when one of the fertilizers activates Each fertilizer can be assigned a separate mixer Before a fertilizer is applied it is possible to mix up the liquid in the tank To do this enter the number of seconds necessary in the pre mixing question Once the injection value of a fertilizer has been entered perma nent intermittent or stop mixing can be carried out For t...

Страница 19: ...aning and the start of another Once the incident in the pressure gauge has been resolved we must access the Manual Filters section to remove the malfunction and thus activate the filter washing control system once again Check chapter 8 If necessary sectors being irrigated can be stopped in order to best optimize pressure In this case the pro grams being run that contain sectors related to the filt...

Страница 20: ...following associated values will be requested With the value per pulse in the irrigation or fertilizer meter we indicate the volume to be counted per pulse received The units for both irrigation and fertilization run from 1 centiliter to 9999 liters The input allows a maximum of 5 pulses per seconds With the delay without pulse minutes that it should be without receiv ing pulses from meter are sho...

Страница 21: ...sector number Indicate whether motor 1 and motor 2 will be starting up automati cally when the selected sector is irrigated Each sector has a separate waterhammer temporization in seconds to adjust the opening and closing of the electrovalves in relation to the motors and changes between sectors The temporization can be positive or negative modify the signs by pressing the or keys With positive va...

Страница 22: ...made to the equipment or facility 1 Erasure allows the memory be entirely erased and also records programs and sectors to be erased 2 Events in the standard version it is not possible to make modifica tions 3 Access codes enables the limited access to the Parameters Functions or Total Erasure sections entering here the 4 digit code re questing access Leave the value at 0 if this is not necessary 4...

Страница 23: ... is the oil pressure gauge of the pump digital input 6 is reserved for connection purposes It has a double function first to detect whether the motor has started up and once this is done to detect a possible pressure error The general parameters will ask for the preheating time prior to each start up attempt This value is set to zero when a heater is not used To get the motor ready for operation t...

Страница 24: ... sequential programming can be used to do so it will be necessary to set up the program in the Parameters Program 6 4 with the type of start unless it is set to do it with starting time 99 00 This function asks directly for the program that is sequential On the screens in the example program 3 will start when 2 ends When one program is sequential to another it will not use the days of the week or ...

Страница 25: ...AMS When various sectors must be irrigated one after another sequential programming may be used This con sists of having an initial program set for certain irrigation days and a start time and the rest of the programs in the irrigation sequence configured in Parameters Programs 6 4 for a type of sequential start In these programs there will be a question regarding Sequential of the program whereby...

Страница 26: ...e highest Using the previous section s example the first time the program starts it will start with program 10 and termi nate with 14 the next time the program is activated it will start with 11 and terminate with 10 and so on First start P10 P11 P12 P13 P14 Second start P11 P12 P13 P14 P10 Third start P12 P13 P14 P10 P11 Fourth start P13 P14 P10 P11 P12 Fifth start P14 P10 P11 P12 P13 Sixth start...

Страница 27: ...rtilizer 3 Pre mixing F1 and F3 Mixer 1 Mixer 3 In parallel fertilization all the fertilizers are applied at the same time once the pre irrigation and correspond ing pre mixing times have terminated Sector Pre irrigation Post irrigation Fert general Fertilizer 1 Fertilizer 2 Fertilizer 3 Pre mixing F1 and F3 Mixer 1 Mixer 3 For all the cases the fertilizer general will remain active on whenever on...

Страница 28: ...ack cleaning or immediate cleaning finish one if one is currently being run and terminate a malfunction due to continuous cleanings In the Clock section the date and time of the internal clock can be modified The clock is updated once we exit the screen by pressing the FUN or CON key When the Agrónic 2500 has no power supply the clock will remain operative for around 48 hours any longer it may sta...

Страница 29: ...gation or fertilizer time and volume totals to zero saving the date when this is done If the access code is activated in the section Parameters Installer it will be requested here In the section on manual outputs the devices connected to them can be activated It is necessary to do this carefully as there is no control over this type of function and the installation may be damaged it does not take ...

Страница 30: ...s to the Functions menu Consultation to the Readings menu second press to the Consultation menu 9 2 READINGS ANOMALIES Anomalies are incidents that are recorded into memory and can be read from this section In addition if any new anomalies have occurred since the last reading the number of them will be listed in the general consultation Anomalies form part of the general record that is stored in t...

Страница 31: ...cording an anomaly Once the incident is resolved the stop must be canceled by access ing Manual Terminate stops 8 Determining factor Temporary stop N34 A digital sensor connected to the input causes the irrigation programs under way to stop and a record to be made of the anomaly the se quential programs or upcoming starts will continue irrigating SMS Message Limit exceeded N45 When using the SMS m...

Страница 32: ...e displayed The fourth line reports the status of irrigation with the number of active sectors and if there are none the text reads No irrigation in process The fifth line displays the general outputs configured the dash indicates its status is inactive and the number means its status is active P General pump or valve F Fertilizer M Mixer C Filter Cleaning The last line displays the status of the ...

Страница 33: ...t screen will list the first twenty programs and a sum mary of their status To the right of each program number is the status indicated by the following symbols Point program inactive R irrigating a postponed d definitive stop Press the down arrow key to display the following screens at the end it switches to sector consultation or the up arrow to view the previous ones at the end it switches to t...

Страница 34: ...ogram independently will display its irrigation units in the format in which they have been configured The fertilizer units will be shown in the same format for all the programs in time or volume When an irrigation program is sequential to another this will be indicated on the last line in addition if the alternate sequencing operative has been activated it may display alternate start when it come...

Страница 35: ...oint the backcleaning will cease to operate and the system waits for the user to terminate the stop by entering the section Manual Filters 8 10 6 CONSULTATION COMMUNICATIONS For this section check the manual Agrónic 2500 Communications Supplement 10 7 CONSULTATION AGRÓNIC This report is based on values related to the equipment itself Here the serial number of the NS equipment is found used for man...

Страница 36: ...s there already is oil pressure which in theory means that the motor is running In this case an anomaly is recorded and irriga tion and motor control continues without making any more start up at tempts Diesel Motor does not start N31 Once the four start up attempts have been made and 30 seconds have passed if the motor is not operating the programs under way that contain the sectors related to mo...

Страница 37: ... specific manual 6 AGRÓNIC CONSULTATION NS 00001 V 1 10 Relays V Out yes V Panel no Vdc 11 8 v 7 FERTILIZER CONSULTATION F1 00118 L M1 000 F2 00073 L M2 024 ope F3 00109 L F4 00043 L M4 000 Cleaning 020 4 PROGRAMS CONSULTATION 01 02f 03f 04 45 06R 07 08 09a 50 N program 00 PROGRAMS CONSULTATION 01 02f 03f 04 25 06R 07 08 09a 30 11 12 13 14 35 36 37 38 39 40 N program 00 PROGRAM CONSULTATION 01 02 ...

Страница 38: ...GRAM 02 Sectors 05 SMTWT S Start 10 30 Irrigation 00266 m3 F1 00045L F2 00105L READINGS 1 Totals 2 Anomalies 1 MANUAL 1 Out of service 2 STOP 3 Program 4 Filters 5 Clock 6 Terminate stops 7 Sectors 8 Totals erasure 9 Outputs 2 3 PARAMETERS 1 Fertilization 2 Filters 3 Generals 4 Programs 5 Sectors 6 Communications 7 Various 8 Installer 4 ...

Страница 39: ...1 yes Temp start 018 Temp stop 012 Stopping the sectors no Pump 2 yes Temp start 005 Temp stop 022 Stopping the sectors yes Assign inputs IM FM1 FM2 FM3 FM4 1 2 0 0 0 Assign inputs SC TM DM CS PS AL 4 2 0 5 0 0 Irrigation meter Value per pulse 0100 00L Delay without pulse 010 Fertilizer meter Value per pulse 0001 00L Delay without pulse 010 Detection delay input SC 030 Detection delay input TM 180...

Страница 40: ...40 NOTES R 1841 4 ...

Отзывы: