Auto Jet Instruction Manual
18
19/04/2018 Rev:2.0.0
CENTRAL VACUUM SYSTEMS
ByTecnoplus
s.r.l.
9 - CONTROL PANEL
- +
- +
- +
TEST
Main Switch
Network presence
warning light
Vacuum line sockets
isolator
Nozzle test button and
pneumatic actuator
RED
potentiometer
GREEN
Potentiometer
BLUE
potentiometer
Main switch:
magnetotherrmic switch for isolatiing and protecting the power supply line of the control
panel.
Warning light :
if on, indicates the presence of power supply at the control panel.
Vacuum line isolator:
switch to isolate the suction activation command in case of maintenance.
TEST button:
by pressing this button it is possible to manually force a material discharge cycle, thus
checking that the AUTO Jet system is working correctly.
RED Potentiometer:
adjustment of the maximum interval time between one discharge and the next
one. In this way it is possible to automatically force the discharge of the material without stopping the
suction.
Adjustment time: 5 to 225 seconds
GREEN Potentiometer:
regulation of door opening time to allow complete emptying of collected mate-
rial inside the AUTO Jet separator.
Adjustment time: 5 to 225 seconds
BLUE potentiometer:
adjustment of nozzle blowing time to facilitate complete emptying of collected
material inside the AUTO Jet separator.
N.B.
The door opening time (RED potentiometer) has priority over the nozzle blowing time.
Adjustment time: 0 ÷ 225 seconds