15
2
19/04/2018 Rev:2.0.0
English
8.5 Connection of the compressed air network
Compressed air
connection G 3/4 “
Connection of compressed air system:
Connect the compressed air system to the G 3/4 “fi tting located on the back of the AUTO Jet system.
It is always advisable to apply the maximum available pressure to the system, always respecting the
limits indicated, so as to be able to have the greatest fl ow rate on the nozzles, in order to assure their
correct operation.
Install a tap for closing the compressed air and a drain valve for the safe maintenance of the
appliance.
Pressure regulation applied to pneumatic actuator:
Before starting the AUTO Jet system, check that the pressure applied to the pneumatic actuator is
between 6 - 10 bar.
Never exceed the maximum pressure of 10 bar to avoid damaging the actuator itself.
In case the pressure is incorrect, adjust the regulator fi lter located on the front panel.
Regulator fi lter
pneumatic
actuator
- CAUTION -
NEVER APPLY PRESSURE OVER
10 BAR OR LOWER THAN 6 BAR
Содержание AUTO Jet TURBIX
Страница 2: ......
Страница 22: ...Auto Jet Instruction Manual 22 19 04 2018 Rev 2 0 0 CENTRAL VACUUM SYSTEMS ByTecnoplus s r l...
Страница 23: ......