sisel ENDA ET4430 Скачать руководство пользователя страница 3

    F

6

 )

 250
 400

C1.SE.
 400

C2.SE.
 400

a1.SE.
 500

a2.SE.
 500

m.SEt
  50

C1.SE.
 400

C2.SE.
 400

a1.SE.
 500

a2.SE.
 500

m.SEt
  50

C1.SE.
 399

C2.SE.
 399

a1.SE.
 499

a2SE.
 499

m.SEt
  49

Tuşuna basılırsa kontrol ve alarm set değerleri ayar konumuna geçilir.

TERMS

( 1 ) 

Indicates measured value and set values in “Running Mode”.

        Indicates the parameters and names in “Programming Mode”.

2

 )

 

       

Increment key in “Running Mode” and “Programming Mode”.

Parameter selection key in “Programming Mode”.

3

 )

 

       

Decrement key

By pressing this key in “Running Mode”, software version can be displayed.

       Parameter selection key in “Programming Mode”.

5

 )

 

Control and Alarm set key in “Runnig Mode”.

        Parameter set key in “Programming Mode”

4

 )

 

Selectable function key

 “Running Mode”.

        Menu selection key in “Programming Mode”.

C

ontrol, Alarm1

, Alarm2, 

SSR 

output and 

status indicator symbols.

  ( 6 ) Status Indicators

  ( 

2

 ),( 

3

 ),( 

4

 ),( 

5

 ) Keypads

Mi

c

ro switch

PV 7 

Segment

  4 

digits

 

green LED

 ,

 

SV 7 

Segment

 4 

digits

 

green

 LED display.

  ( 1 ) PV 

and

 SV 

Indicators

PV Display 12.0mm , SV Display 8.13mm

Character Height

ALARM1 AND ALARM2 OUTPUT TYPES

 A1.St.

Hi

 A1.St.

lo

 

A1.St.

Lo

 

A1.St.

Hi

ASV

SV

SV

SV

SV+ASV

SV+ASV

SV-ASV

OFF

OFF

OFF

OFF

-300

300

+300

300

ON

ON

ON

ON

a1,Hy

A1.Hy

A1.Hy

A1.Hy

 Independent Alarm
 

A1.tp.

=

indE

 Deviation Alarm

 A1.tp

dE.

 Band 

Alarm

 

A1.tp.

bAnd

SV    = CONT output set value       

    

ASV = Alarm output set value

(ASV min.  =-300, ASV maks. = +300)

(ASV min.  = beginning of scale
 ASV max. = end of scale)

  (ASV min. = 0,  ASV ma

x

. = +300)

SV =CONT 

output

 set 

value

     ASV = AL1 

output

 set 

value

 

Band Alarm With Inhibition

          

A1,tp.

bAn.i

ON

OFF

B

eginning

Band alarm 

is possible

SV

SV+ASV

SV-ASV

ON

OFF

Band alarm

 is possible

B

eginning

SV

SV+ASV

SV-ASV

SV =Set point of CONT output       ASV = Set point of AL1 output      (ASV min. = 0,  ASV max. = 300 )

SETTING UP ALARM CONTROL AND SETPOINT VALUES

If one of the 

d.in.c.

 or 

f.kE.c.

 parameters are 

set to the 

C2.S.A.

 value, this parameter can 

be displayed.

If one of the 

d.in.c.

 or 

f.kE.c.

 parameters are 

set to the 

mAnu.

 and if 

C. Pb

 is different from 0 , 

this parameter can be displayed.

If the 

C.O.SE.

 parameter is set to SSR out, this 

parameter can be displayed.

3 seconds later

3 seconds later

3 seconds later

3 seconds later

3 seconds later

3 seconds later

 pfa
 400

 400

____
 400

----

No communication with sensor.

(Sensor and/or cable broken or 

not connected)

ERROR MESSAGES

Temperature value is higher 

than scale.

Temperature value is lower 

than scale.

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:18

 

3

/4

ET4430-EN-01-190116

ENDA

TM

TEMPERATURE CONTROLLER

ET4430

     

SSR

F

Содержание ENDA ET4430

Страница 1: ...screw terminal connections 1 5mm EN 61326 1 2013 Performance criterion B satisfied for EN 61000 4 3 standard EEPROM minimum 10 years Max 100 Ohm EN 61010 1 2010 Pollution degree 2 overvoltage category...

Страница 2: ...pplement to cables Connect the thermocouple cables to the right places at the input terminal For resistance PT100 Sensor In order to using 2 wire resistance sensors PT100 8th and 9th terminals must be...

Страница 3: ...ent Alarm A1 tp indE Deviation Alarm A1 tp dE Band Alarm A1 tp bAnd SV CONT output set value ASV Alarm output set value ASV min 300 ASV maks 300 ASV min beginning of scale ASV max end of scale ASV min...

Страница 4: ...m bAnd Band alarm bAn i Band with inhibition A2s t Status selection for Alarm2 Output If Hi is selected A2 output is above the Alarm2 set value ON If lo is selected A2 Output is above the Alarm2 set v...

Страница 5: ...rm 2 Band alarm 3 Active alarm after in band time ModBus device address Adjustable between 1 and 247 Modbus communication speed Baudrate 0 Modbus cancel 1 2400 bps 2 4800 bps 3 9600 bps 4 19200 bps 5...

Страница 6: ...d 002Dh 0047d 002Fh 0048d 0030h 0049d 0031h 0050d 0032h 0051d 0033h 0052d 0034h 0041d 0029h 0042d 002Ah H41 H43 H44 H45 H47 H46 H48 H49 H50 H51 H52 H40 H42 R W R W R W R W R W R W R W R W R W R W R W...

Страница 7: ...the query is not an allowable action for the slave If a Poll Program Complete command was issued this code indicates that no program function preceded it The data address received in the query is not...

Отзывы: