61 30 459 D 3497
18
D 3497
.
201.01.04
.
02 06.2009
6 Operation
Sirona Dental Systems GmbH
Programs
Operating Instructions inFire HTC
6.4.2
Select program number/load program
Select program number
1. Press the Load Program key.
ª
The
LOAD PROGRAM
screen is displayed. The cursor is on the
program number.
2. Enter the desired program number with the numeric keys or press key
"S4" repeatedly until the desired program number appears.
Loading a program
➢ Press the "S2" key (=
YES
) to confirm the loading process.
ª
The standby display is shown.
To quit the menu immediately, press the "S1" key (=
NO
).
6.4.3
Starting the program
➢ Press the START/STOP key to start the process.
ª
The LCD displays shows the stand-by screen. In the top line, the status
READY
changes to
RUN
. Blinking or illumination of the stage LCD
indicates that a process is running. Passed program stages are no longer
lit when they are completed.
You can pause the current program by pressing the START/STOP button
again.
6.4.4
Starting a program with the Casting-Time function
1. Select the desired program with the Load Program [
18] key.
2. Press the Casting-Time key.
ª
The LCD display shows the following screen:
1. Press the S1 key to set the desired casting time of the program.
2. Enter the day of the week with the numeric keys (MO=1, TUE =2, WED=3
..., SUN=7)
3. Enter the desired casting time (hh:mm) with the numeric keys.
4. Press the START/STOP key.
ª
The LCD display now indicates the program start in line "S1." The The
casting time function is now activated; there is no need to press any
further key for confirmation.
To quit the program press the Casting-Time key again.
05
IVOCLAR
VIVADENT
IPS e.max
ZirCAD
Program
No.
Designation
/min
min
S4
S3
S2
S1
/min
min
S4
S3
S2
S1