A combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions
given in section 3 site requirements.
No purpose provided ventilation is normally required for this appliance.
The requirements of other appliances operating in the same space or room, and the results of a spillage
test must be taken into consideration when assessing ventilation requirements, this will have been carried
out by your Gas Safe registered installer.
For Republic of Ireland, ventilation may be required, see IS 813, ICP3, IS 327, and any other
rules in force.
OPERATING THE APPLIANCE (Manual Control)
For your safety, the fire is fitted with a Flame Supervision Device (FSD), which will shut off the
Gas supply if for any reason the pilot is extinguished.
This device incorporates a fixed probe, which senses heat from the pilot burner flame, if the probe is
cooled, the device will prevent any gas flow.
If for any reason the flames go out or if the fire has been turned off for any reason, always
WAIT FOR
3 MINUTES
before attempting to re-light.
The pilot is visible through the Fuel bed at the front of the fire; rotate the coals for good
viewing.
Push in and turn the control knob to the SPARK position, and hold there for a few seconds.
Continue turning anti-clockwise through the spark click to the PILOT light position, ensuring
that the control knob is depressed and the pilot has lit. If not, return the knob clockwise, and
repeat.
When the pilot lights after the spark, keep the knob depressed for approximately ten to
fifteen seconds.
Now release the knob and the pilot should stay alight.
If the pilot is extinguished during use, wait three minutes before repeating the ignition
procedure.
To achieve the HIGH setting, push the control knob in slightly and continue turning anti-
clockwise to the high position.
OFF
IGNITION
LOW
HIGH