The use of charcoal filters is not necessary
in this case.
Installation of air outlet joint diameter
200mm.
(THIS ITEM IS SUPPLIED WITH POWERFUL
MOTORS ONLY)
In case of installation of the air outlet dia-
meter 200mm which is possible on the upper
side of this ceiling hood only, please follow
these instructions.
Make the opening for the air outlet diame-
ter 200mm on the upper side of the product
(this opening is already marked on the body
of the unit.
Install the joint diameter 200mm supplied
with the external motor and fix it through the
8 screws supplied.
The joint diameter 200mm is slightly moved
from the longitudinal axis of the product by
25mm.
In case of built-in i
nstallation , you need
to remove the stainless
steel cover
( Fig. 11), that is used
with the freestanding
version only.
EXTRACTION VERSION – INTERNAL MOTOR
(BUILT IN)
The appliance is ‘factory-set’ with the air-
outlet placed in its shorter side, but you can
choose your desired air-outlet side , by fol-
lowing these steps:
Open the glass panels, by following the in-
structions given in the OPERATION MODE
section, and remove the grease filter .
Remove the 4 screws, as shown in figure 4.
Remove the lower metal sheet , as shown in
figure 5.
Remove the motor securing screws , as shown
in figure 6
Open the hole either in the centre of the
hood upper side (fig.7) or longer side (fig.
12). Close the hole where the motor was pre-
viously housed and secure the steel plug by
tightening the four screws supplied (fig. 9).
Fit the motor on the hood upper side, by
using the 4 screws previously removed
(fig.10) or fit the motor on its specific hou-
sing, as shown in Fig. 19, in case you choose
to fit the air out-let in the longer side of the
appliance .
Bring the appliance close to the ceiling and
push the power cord through the specific
pass (fig.2).
Secure the hood to the ceiling , by tightening
the nuts supplied to the threaded bars.
Perform the electric connection into the po-
wer supply metal box found inside the ap-
pliance.
Connect the air exhaust pipe to the motor air
out-let flange .
If you choose to fit the air out-let in the
hood shorter side, you can make the pipe fi-
xing operation easier by removing the cover
shown in fig. 16.
The use of charcoal filters is not necessary
in this case.
BUILT-IN INSTALLATION
15
Содержание SLT960
Страница 10: ...10 50 1 4 5 6 2 3 ...
Страница 11: ...11 51 7 8 10 9 11 12 ...
Страница 12: ...12 52 13 14 15 16 17 18 ...
Страница 13: ...13 53 19 20 21 22 23 Energiatanúsítvány Külső motor Energiatanúsítvány termék külső motoros változatban ...
Страница 17: ...CONTENTS Warnings Uses Free standing installation Built in installation Working Maintenance 12 GB ...
Страница 24: ...50 1 4 5 6 2 3 ...
Страница 25: ...51 7 8 10 9 11 12 ...
Страница 26: ...52 13 14 15 16 17 18 ...
Страница 27: ...53 19 20 21 22 23 ...
Страница 28: ...54 ...
Страница 29: ...55 ...
Страница 30: ...90001101123 GM 04 15 ...