5
System integration
The HSD626EXP dome camera can be integrated into other suppliers' surveillance systems in
two ways:
● Via the Open Streaming Architecture (OSA) application programming interface (API). For
more information see the Siqura Programming Interface document or contact your supplier
for details.
● Via serial tunneling using the Pelco D protocol. For Pelco D, set both the UART gap timeout
and the UART max latency to 7. This ensures efficient and accurate transmission of the
commands. Other serial servers will likely use different terms for these settings. The
HSD626EXP's default baud rate is set to 9600. Ensure that your control keyboard uses a
compatible baud rate. The factory set ID number is 1 and you must not change this
setting. For applications that require a unique RS-485 ID, please contact Siqura for
assistance.
20