2

Safety and compliance

This chapter gives the HSD626EXP safety instructions and compliance information.

In This Chapter

2.1 Safety................................................................................................................... 6

2.2 Cautions................................................................................................................8

2.3 Compliance............................................................................................................9

2.1

Safety

The safety information contained in this section, and on other pages of this manual, must be
observed whenever this unit is operated, serviced, or repaired. Failure to comply with any
precaution, warning, or instruction noted in the manual is in violation of the standards of
design, manufacture, and intended use of the module. Siqura assumes no liability for the
customer's failure to comply with any of these safety requirements.

Trained personnel

Installation, adjustment, maintenance, and repair of this equipment are to be performed by
trained personnel aware of the hazards involved. For correct and safe use of the equipment
and in order to keep the equipment in a safe condition, it is essential that both operating and
servicing personnel follow standard safety procedures in addition to the safety precautions
and warnings specified in this manual, and that this unit be installed in locations accessible to
trained service personnel only.

Safety requirements

The equipment described in this manual has been designed and tested according to the
UL/IEC/EN 60950-1 safety requirements. See the CE Declaration of Conformity for
compliance information.

Warning: If there is any doubt regarding the safety of the equipment, do not put it into
operation. 

This might be the case when the equipment shows physical damage or is stressed beyond
tolerable limits (for example, during storage and transportation).

Important: Before opening the equipment, disconnect it from all power sources.

The equipment must be powered by a SELV1 power supply. This is equivalent to a Limited
Power source (LPS, see UL/IEC/EN 60950-1 clause 2.5) or a "NEC Class 2" power supply.
When this module is operated in extremely elevated temperature conditions, it is possible for
internal and external metal surfaces to become extremely hot.

1. SELV: conforming to IEC 60950-1, <60 Vdc output, output voltage galvanically isolated
from mains. All power supplies or power supply cabinets available from Siqura comply with
these SELV requirements.

 6 

Содержание HSD626EXP

Страница 1: ...HSD626EXP Explosion protected IP PTZ dome camera Installation Manual...

Страница 2: ...r respective owners Liability Siqura accepts no liability for claims from third parties arising from improper use other than that stated in this manual Although considerable care has been taken to ens...

Страница 3: ...sions 12 4 Dome camera setup 13 4 1 Switch definition 13 4 2 Communication switch configuration 14 4 3 Establish a network connection 15 4 4 System compatibility 16 4 5 RJ 45 to SFP changeover 16 4 6...

Страница 4: ...work technologies and Internet Protocol IP Video audio and contact closure transmissions Video compression methods Windows environments Web browsers Before you continue Before you continue read and ob...

Страница 5: ...the open source Free Type font rendering library The Open Source Libraries and Licenses document available at Siqura gives a complete overview of open source libraries used by Siqura video encoders an...

Страница 6: ...ns and warnings specified in this manual and that this unit be installed in locations accessible to trained service personnel only Safety requirements The equipment described in this manual has been d...

Страница 7: ...r is responsible for ensuring that the label depicted below background yellow border and text black is present in the restricted locations where this equipment is installed EMC This device has been te...

Страница 8: ...that it will never be classified as reactive hazardous waste It is safe for normal disposal as required for batteries by your local authority 2 2 Cautions Handle the camera carefully Do not abuse the...

Страница 9: ...2 3 Compliance Safety and compliance 9...

Страница 10: ...ompensation Wide Dynamic Range Electronic Image Stabilisation 400 second preset targeting 360 endless panning 256 presets 8 programmable cruises 8 alarm in 1 output Two way audio 8 Privacy Masks Analo...

Страница 11: ...n proof housing with dome body inside 30 cm cable harness for power supply video and RS 485 CD Product documentation includes HSD62x User Manual and HSD626EXP Installation Manual Printed product docum...

Страница 12: ...3 4 Dimensions Product description 12...

Страница 13: ...angeover 16 4 6 Dome cable definition and requirements 17 4 1 Switch definition It is necessary that the dome ID and communication protocol remain in the default modes when connecting the HSD626EXP to...

Страница 14: ...advised to verify the accuracy of the communication switch configuration but do not change the default settings or some functions may not work properly Communication switch Switch Description 1 RS 485...

Страница 15: ...igure the network adapter of the PC once more to assign the PC to the same subnet as the unit Step 1 Set the PC to the factory set subnet of the unit To configure the network adapter on the PC 1 In Co...

Страница 16: ...the settings 4 4 System compatibility To ensure system compatibility download the latest firmware at http www siqura com 4 5 RJ 45 to SFP changeover To install the SFP interface safely into the HSD626...

Страница 17: ...connector Important Be sure to follow the safety instructions with regards to optical safety and fiber handling precautions 4 6 Dome cable definition and requirements For operation the HSD626EXP came...

Страница 18: ...whether you have established an Ethernet connection Ethernet socket LEDs green yellow Green on off 100 10 Mbit Yellow on blink link OK active Yellow off flash link down TX attempt 4 6 3 22 pin cable h...

Страница 19: ...elay output 300 V 7 Audio in Yellow black 8 Audio out Orange black 9 Audio GND Green black 10 Audio GND Brown black 11 ISOG Blue white 12 Alarm 1 Red white Input 5 V 10 K pull up Photo Relay output 30...

Страница 20: ...unneling using the Pelco D protocol For Pelco D set both the UART gap timeout and the UART max latency to 7 This ensures efficient and accurate transmission of the commands Other serial servers will l...

Отзывы: