2 Chapter I Overview
AC distribution unit. It operates in different modes according to the need.
The storage inverter plays a core role in the whole system and is characterized with high conversion efficiency, wide range
input voltage, rapid on/off-grid switching and convenient maintenance. It has a complete protection function (such as islanding
protection, DC overvoltage protection, AC overvoltage-under-voltage protection, over-frequency/under-frequency protection,
inverted sequence protection and output overload protection) and can meet on/off-grid operation requirements. The input side
of the storage inverter can be 1-Sting Configuration, 4-Sting Configuration and 8-Sting Configuration.
Battery
bank
PCS
Grid
AC
distribution
box
Fig.1-2 Energy storing system diagram
Attention
PWS1-500KTL- NA storage inverter is without an isolation transformer.
An External Transformer IS required to be deployed between the inverter and the Utility
Power Grid.
The External Transformer shall be compliant to the following conditions:
Comply with ANSI C57.12.50-1981(R1998) or ANSI/UL1561
Capacity shall be 500KVA
The primary voltage and secondary voltage shall be - Grid Voltage (480V in US, et al ):400V
Be Isolated transformer
Safety instructions
This user’s manual is about installation and use of Sinexcel PWS1-500KTL-NA storage inverter without transformer.
Before installation, please read this user’s manual carefully.
The storage inverter must be commissioned and maintained by the engineers designated by the manufacturer or the
authorized service partner. Otherwise, it might endanger personal safety and result in device fault. Any damage against the
device caused thereby shall not be within the warranty scope.
The storage inverter is only used for commercial/industrial purposes, and it cannot be used as an energy saving device related
to life support device.
Danger
Содержание PWS1-500KTL-NA
Страница 1: ...Sinexcel PWS1 500KTL NA Grid Support Utility Interactive Energy Storage Inverter ...
Страница 2: ......
Страница 4: ......
Страница 7: ...Appendix 2 Quality assurance and after sales service 39 Installation Records 41 ...
Страница 8: ......
Страница 19: ...Chapter IV Device Installation 11 Fig 3 4 Appearance diagram for PWS1 500KTL NA storage inverter ...
Страница 34: ...26 第六章 操作控制显示面板 6 5 4 AC settings ...
Страница 35: ...27 Fig 6 7 AC settings ...
Страница 41: ...第六章 操作控制显示面板 33 ...
Страница 45: ...Chapter VII Communication Mode 37 Fig 7 5 Structure diagram for background monitoring system ...
Страница 49: ...Installation Records ...