EM330D User Manual
A Special Purpose Inverter for Hoisting
26
Relay Output
EA-EC
Relay NO terminal
Contact drive capability
250VAC:3A, COS
>0.4
30VDC:1A
EB-EC
Relay NC terminal
Multi-function
Output
Y1
OC output terminal 1
See description of F2-12, F2-13, F2-18 for
programmable multi-functional output terminals
Maximum output current: 50mA
Y2
OC output terminal 2
D0*
High speed pulse output
terminal*
Analog Output
M0
Analog output terminal 0 Analog output 0~10V or 0~20mA can be defined
by setting of F2-16, F2-17.
M1
Analog output terminal 1
Auxiliary
Power Supply
10V-GND
Power supply of analog
quantity terminal
+10V/20mA
,
commonly used for the mains of
potentiometer.
24V-COM
Power supply of switching
value terminal
Maximum output current: 150mA
COM
Switching value common
terminal
Switching value input/output signal common
terminal
Communication
A+
RS485 communication
terminal
RS485 Communications input(+)
A-
RS485 Communications input(-)
Shield
PE
Shielded grounding
For shielded terminal cable grounding
3.3.2.1
Wiring the Analog Input Terminals
Wiring terminals VS and VF through analog voltage signal:
When analog voltage input signal is as the external power supply, wire terminals VS
and VF as per the method shown in Figure 3-12-a.
When analog voltage input signal is as the potentiometer, wire terminals VS and VF as
per the method shown in Figure 3-12-b.
VS/VF
GND
PE
EM330D
Shield cable grounded
0~10VDC
VS/VF
EM330D
10V
GND
PE
Figure 3-12 Wiring of Terminal VS and VF
Wiring terminals IS and IF through analog current signal:
IF
EM330D
Shield cable grounded
IS
GND
0~20mA
0~20mA