EM330D User Manual
A Special Purpose Inverter for Hoisting
12
1.3.2
Start/Stop Control Mode of Inverter
The start/stop control mode of inverter refers to the modes to start/stop control of
inverter. There are 3 control modes: keypad control mode, terminal control mode, and
RS485 communication control mode. Terminal control mode is categorized as 2-wire
sequence, and 3-wire sequence. See Figure 1-1 for the control logic of terminal control
mode.
24V
PLC
RUN
Xi
COM
F/R
K1
K2
Run
Command
K2
K1
0
0
0
1
1
0
1
1
Reverse
Forward
Stop
Stop
24V
PLC
RUN
Xi
COM
F/R
K1
K2
Run
Command
K2
K1
0
0
0
1
1
0
1
1
Stop
Forward
Reverse
Stop
0: On 1:Off
0:On 1:Off
(a) 2-wire sequence 0 (F0-05=0)
(b) 2-wire sequence 1 (F0-05=1)
Forward
Button
RUN
Stop
Button
24V
PLC
RUN
Xi
COM
F/R
Run
Button
RUN
Xi
F/R
1
0
Stop
Button
Forward
Reverse
0: On 1: Off
( c ) 3-wire sequence 0 (F0-05=2)
(d) 3-wire sequence 1(F0-05=3)
F/R
Xi
Reverse
Button
24V
PLC
RUN
Xi
COM
F/R
Figure 1-1 Control Logic of Terminal Control Mode
1.4
EM330D Outlook
See Figure 1-2 for the outlook of EM330D (Instance: EM330D- 4.0kW).
Figure1-2 EM330D Outlook
The face terminal cover can be taken away by following the arrow shown in Figure1-2.
EM330D