2.After finishing installation,check if drainage water flows smoothly.
Add approximately 600 cc of water to the drainage trough through air outlet or inspection hole slowly and check
drainage flow.
When electric wiring is finished,check drainage flow during cooling operation.
Indoor unit installation
Method of adding water.
Warning:Befone obtaining access to terminals, all supply circuits must be disconnected.
Electric wiring
All field supplied parts and meterials must conform to local laws and regulations.
For electric wiring,refer to WIRING DIAGRAM attached to the unit body.
All wiring must be performed by a skilled technician.
A circuit breaker capable of shutting down power supply to the entire system and which have at least 3 mm contact
seperation in each jole must be install in the fixed wiring.
Earth properly.
Wiring must conform to national laws and regulations.
The fixed wiring must be installed with a protector with no more that 30 mA leakage current.
If the supply cord is damaged, it must be replaced by the manufactory or its service agents or a similarty qualified
person in order to avoid a hazard.
Wiring of unit and the controller
Wiring of the indoor unit.
Remove the control box lid(1),pull the wires inside through rubber bush
and wiring according to the WIRING
DIAGRAM , then tighten it with clamp.
Wiring of the controller
Remove the control box lid(2),pull wires inside through rubber bush
and connect to the controller.
Wrap the wire with sealing pad(12).
After wiring,tighten it with clamp and fix the control box lid(1),(2).
Heating and cooling:connect the rubber wire (5-cords) to the power supply terminal board in properly.
Cooling:connect the rubber wire (3-cords) to the power supply termiral board properly.