8
Set the function to “COOLING”. The settable temperature range is between 17 and 30 degrees. This can be
set using the temperature control.
The air with high oxygen content cooled by the unit is fed into the room via the air hose. This can be
executed e.g. via a tilted window, a door or wall aperture. Make sure that no warm outside air can enter the
room. For effective cooling, we recommend our selection of various accessories which reduce or prevent
entry of warm air into the room, or via the remote control.
Using the “Comfort Control Kits” you can also control the unit from inside using the remote control. The
“Comfort Control Kit” set is additional accessories. It is possible to buy it at the seller or supplier.
After switching on, or over, the ventilator operates, but the compressor only starts after the control lamp has flashed for three minutes.
Cooling effect may require a further 10 minutes. Further information is available under the item, “Troubleshooting”.
HEATING
9
On cold days it is recommendable to start the unit early in order to avoid intensive cooling of the room.
9
For the heating function and to improve the heating effect and avoid lower temperatures (lower than
17°C) we recommend you remove the rubber plug from the condensation water outlet and allow the
condensatation water to leak out of the unit using the drainage hose. However, the drainage hose does not
have to be connected in the heating mode, Please make sure that the condesnation water outlet is closed
with the rubber cap during operation. In such a case, proceed analogously to the emptying of the water tank
in the cooling function.
9
The heating function of the unit must not be operated at a room temperature of more than 23°C or less
than 7°C. The unit can also be operated with heating function, if the outside temperature is lower than 7°C.
However, you must then ensure that the unit is operated inside and the room temperature is at least 7°C.
HEATING IN INDOOR OPERATION
The unit is in the room to be heated.
The cold extract air has to be fed out of the room via the air hose. This can be executed e.g. via a tilted
window, a door or wall aperture. Make sure that no warm outside air can enter the room. For effective
heating, we recommend our selection of various accessories which reduce or prevent entry of cold air into
the room.
Set the function to “Heating”. The settable temperature range is between 15 and 25 degrees target
temperature. You can set this using the temperature control.
After switching on, or over, the ventilator operates, but the compressor only starts after the control lamp has flashed for three minutes.
Cooling effect may require a further 10 minutes. Further information is available under the item, “Troubleshooting”.
Caution: In the heating mode, separate setting of the ventilator is not provided, since the
highest ventilation level is already preset to avoid overheating of the unit.
Caution: Connect the air hose and the air outlet grid to the unit as displayed in the
illustration; the air hose connection piece and air outlet grid need to be exchanged.