7
COOLING
9
It is recommended to start the unit early on hot days, thus avoiding heating up of the room.
9
This unit has a self-evaporation function for condensation water, so that it is normally not necessary to
empty the water tank in cooling mode. The drainage hose need not be connected. Please make sure that
the outlet is closed with the rubber cap during operation.
(This does not apply in the case of high air humidity. If the unit operates in cooling mode for a longer period and especially at a time
of year with high air humidity, the condensation tank may be full. The control lamp will remind you to empty the water. Refer to error
message E4. In such a case, empty the water tank via the condensation water outlet. If continuous high air humidity is likely, it is
recommended to drain the condensation continuously via the drainage hose.)
COOLING IN INDOOR OPERATION
The unit stands in the room to be cooled.
Connect the air hose and the air outlet grid to the unit as displayed in the illustration; the air hose
connection piece and air outlet grid need to be exchanged.
The warm extract air must be emitted from the room via the air hose. This can be executed e.g. via a tilted
window, a door or wall aperture. Make sure that no warm outside air can enter the room. For effective
cooling, we recommend our selection of various accessories which reduce or prevent entry of warm air into
the room.
Place the function to “COOLING”. Set the target temperature using the temperature control. The settable
temperature range is between 17 and 30 degrees target temperature. The unit must only be used in an
ambient temperature of maximum 32°C.
Note: After switching on, or over, the ventilator operates, but the compressor only starts after the control lamp has flashed for three
minutes. Cooling effect may require a further 10 minutes. Further information is available under the item, “Troubleshooting”.
COOLING IN OUTDOOR OPERATION
The unit is outside the room to be cooled.
Connect the air hose and the air outlet grid to the unit as displayed in the illustration; the air hose
connection piece and air outlet grid need to be exchanged.
Place the unit in the shade if possible and in a cool place in order to increase efficiency and to avoid
overheating. At an ambient temperature of over 32 degrees, the unit may deactivate. If this occurs
continuously, we recommend you temporarily use the INDOOR OPERATION of the unit. We recommend
that a drainage hose for condensation water be connected.