Page 47
MARIS ECDIS900 Installation Manual
SIS4000-M
K
2
INSTALLATION AND CONFIGURATION
PREPARATIONS
Install the box, connect the sensors and power up. At least one sensor must be active (yellow
LED above connection is blinking). If there is no activity, the box is in sleep mode and
cannot be programmed from Sensor Monitor.
PROGRAMMING THE IP ADDRESS
1.
Fit a jumper across the pins located above the power input. This forces the IP address
to 192.168.5.33.
2.
On the controlling ECDIS900 computer, change the sensor network IP address to
192.168.5.200.
3.
The box has a web interface for easy programming. Start Internet Explorer and go to
192.168.5.33.
4.
Select Set Default Values, answer Yes and click Ok.
5.
Select Network Settings.
Change IP address to 192.168.4.100.
Change Gateway to 192.168.4.1.
Change Network mask to 255.255.255.0.
Click SAVE.
6.
Select Restart Device, answer Yes and click Ok.
7.
Remove the jumper.
8.
On the controlling ECDIS900 computer, change the sensor network IP address back to
192.168.4.200.
9.
Log on again and verify settings!
SIS4000 after IP configuration.
Содержание Maris ECDIS900
Страница 1: ...ENGLISH Maris ECDIS900System Installation Manual www navico commercial com ...
Страница 40: ...Page 40 MARIS ECDIS900 Installation Manual ECDISMK15 MECHANICAL DRAWINGS ...
Страница 41: ...Page 41 MARIS ECDIS900 Installation Manual DIMENSIONAL DRAWINGS FOR 19 TERMINAL LAYOUT FOR 19 ...
Страница 42: ...Page 42 MARIS ECDIS900 Installation Manual DIMENSIONAL DRAWINGS FOR 24 TERMINAL LAYOUT FOR 24 ...
Страница 43: ...Page 43 MARIS ECDIS900 Installation Manual WIRING DETAILS FOR MK15 HATTELAND FLAT PANEL COMPUTERMK15 ...
Страница 44: ...Page 44 MARIS ECDIS900 Installation Manual HATTELAND MONITORHD26T21 ECDIS900 PCMK5 ...
Страница 63: ......
Страница 64: ... 988 10960 003 www navico commercial com ...