Page 30
MARIS ECDIS900 Installation Manual
GENERAL SETTINGS
g)
Turn on checksum for all sensors (release the button “Check Checksum”).
h)
Do not use sensor data routing except for input to the VDR or PAYS.
i)
Turn off Immediate Data Forward if no PCRadar Kit is installed.
j)
Verify Network Mode is selected. There is no communication to/from other computers
if Sensor Monitor runs in Local Mode.
k)
If the vessel is equipped with a MARIS VDR, then connect the AIS sensor to the VDR
and one of the ECDIS computers. Go to the AIS sensor in the VDR and enable AIS
Target Table filter with 15 NM range and 150 targets. Turn OFF Target Sending by
placing a tick mark in the box, forcing the AIS sensor into receive-only mode. More
than one active connection in the system generates a lot of network traffic and may
overload the computers.
l)
Enable AIS Target Table filter with 15 NM range and 150 targets in the ECDIS
computer.
DISPLAY CONTROLLER MARIS ECDIS900 MK15/16
Verify correct Display Controller is installed.
Select port COM2 for HTC01 computer. Select port COM1 for MK5 computer. When using the
monitor, the Y-cable is used for connection between computer and monitor/alarm panel. The
sensor also controls the alarm sound, check that ECDIS900 alarms give an audible sound from
the monitor. Check that colors look right. If not, check the connection of the serial cable
between the units and make a factory reset of the monitor.
Every monitor comes with its own unique color table, which the Sensor Monitor downloads
and installs. If this does not happen, either the cable is missing or connected to the wrong
port or the configuration is wrong. You can always force a download by deleting the
sensor and creating it again.
CREATING SENSORS
Install the SIS4000-Mk2 box first!
Read more about the installation and configuration in the
. Then continue with the other sensors.
NMEA0183 SENSOR
This sensor is used for almost all connected equipment such as GPS, gyro, log, ARPA, wind,
echo sounder etc. Try this sensor first. If it does not work, select one of the dedicated
sensors.
AIS TRANSPONDER SENSOR
Remote control from the ECDIS900 is possible but is turned off by default.
If the master wants that function enabled, place a tick mark in the box ‘Send data to the
transponder’ and connect the output from the sensor to the AIS for two-way data.
Содержание Maris ECDIS900
Страница 1: ...ENGLISH Maris ECDIS900System Installation Manual www navico commercial com ...
Страница 40: ...Page 40 MARIS ECDIS900 Installation Manual ECDISMK15 MECHANICAL DRAWINGS ...
Страница 41: ...Page 41 MARIS ECDIS900 Installation Manual DIMENSIONAL DRAWINGS FOR 19 TERMINAL LAYOUT FOR 19 ...
Страница 42: ...Page 42 MARIS ECDIS900 Installation Manual DIMENSIONAL DRAWINGS FOR 24 TERMINAL LAYOUT FOR 24 ...
Страница 43: ...Page 43 MARIS ECDIS900 Installation Manual WIRING DETAILS FOR MK15 HATTELAND FLAT PANEL COMPUTERMK15 ...
Страница 44: ...Page 44 MARIS ECDIS900 Installation Manual HATTELAND MONITORHD26T21 ECDIS900 PCMK5 ...
Страница 63: ......
Страница 64: ... 988 10960 003 www navico commercial com ...